How important is it to consider target properties and hematocrit in bloodstain pattern analysis?. (September 2016)
- Record Type:
- Journal Article
- Title:
- How important is it to consider target properties and hematocrit in bloodstain pattern analysis?. (September 2016)
- Main Title:
- How important is it to consider target properties and hematocrit in bloodstain pattern analysis?
- Authors:
- Kim, Sungu
Ma, Yuan
Agrawal, Prashant
Attinger, Daniel - Abstract:
- Highlights: Impact of blood drops on targets with varying material and roughness was investigated. A procedure is described to measure hematocrit during bloodstain pattern analysis experiments. Correlations relating the stain size and velocity of impact were developed. Uncertainty in hematocrit induces significant errors in BPA trajectory reconstruction. Consideration of target surface is needed for accurate BPA trajectory reconstruction. Abstract: Trajectory reconstruction from inspection of bloodstain patterns is relevant to crime scene investigation. While the influence of target properties on trajectory reconstruction has been often qualitatively discussed, it has rarely been quantified. Similarly, a few impact studies measure the viscosity of the blood used in impact experiments. In this work, the impact of blood drops is investigated on targets with a range of surface roughness and surface material. The maximum spreading is characterized using a spreading correlation, which relates the ratio of stain diameter to drop diameter with the non-dimensional numbers Reynolds number and Ohnesorge number. The process for obtaining individual spreading correlations for each of the target substrates and for measuring the viscosity of the respective blood samples is described extensively. The error in estimating the drop release height, associated with using an impact correlation unspecific to the target of interest, is estimated analytically and numerically using experimentalHighlights: Impact of blood drops on targets with varying material and roughness was investigated. A procedure is described to measure hematocrit during bloodstain pattern analysis experiments. Correlations relating the stain size and velocity of impact were developed. Uncertainty in hematocrit induces significant errors in BPA trajectory reconstruction. Consideration of target surface is needed for accurate BPA trajectory reconstruction. Abstract: Trajectory reconstruction from inspection of bloodstain patterns is relevant to crime scene investigation. While the influence of target properties on trajectory reconstruction has been often qualitatively discussed, it has rarely been quantified. Similarly, a few impact studies measure the viscosity of the blood used in impact experiments. In this work, the impact of blood drops is investigated on targets with a range of surface roughness and surface material. The maximum spreading is characterized using a spreading correlation, which relates the ratio of stain diameter to drop diameter with the non-dimensional numbers Reynolds number and Ohnesorge number. The process for obtaining individual spreading correlations for each of the target substrates and for measuring the viscosity of the respective blood samples is described extensively. The error in estimating the drop release height, associated with using an impact correlation unspecific to the target of interest, is estimated analytically and numerically using experimental data. A similar analysis is done when the hematocrit of the blood is assumed rather than measured. Both assumptions lead to significant errors in estimating the release height of a blood droplet. … (more)
- Is Part Of:
- Forensic science international. Volume 266(2016)
- Journal:
- Forensic science international
- Issue:
- Volume 266(2016)
- Issue Display:
- Volume 266, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 266
- Issue:
- 2016
- Issue Sort Value:
- 2016-0266-2016-0000
- Page Start:
- 178
- Page End:
- 184
- Publication Date:
- 2016-09
- Subjects:
- Bloodstain pattern analysis -- Drop impact -- Trajectories -- Hematocrit -- Surface roughness -- Wettability
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2016.05.015 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7378.xml