Comparison of endothelium-dependent and -independent vasomotor response after abluminal biodegradable polymer biolimus-eluting stent and persistent polymer everolimus-eluting stent implantation (COMPARE-IT). (1st January 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of endothelium-dependent and -independent vasomotor response after abluminal biodegradable polymer biolimus-eluting stent and persistent polymer everolimus-eluting stent implantation (COMPARE-IT). (1st January 2016)
- Main Title:
- Comparison of endothelium-dependent and -independent vasomotor response after abluminal biodegradable polymer biolimus-eluting stent and persistent polymer everolimus-eluting stent implantation (COMPARE-IT)
- Authors:
- Puricel, Serban
Kallinikou, Zacharenia
Espinola, Jaqueline
Arroyo, Diego
Goy, Jean-Jacques
Stauffer, Jean-Christophe
Baeriswyl, Gérard
Smits, Pieter Cornelis
Cook, Stéphane
Togni, Mario - Abstract:
- Abstract: Background: Drug-eluting stents (DES) have been associated with local endothelial dysfunction in the segments proximal and distal to the stent (peristent segments) and increased thrombotic risk in long term follow-up. Little data exists on endothelial function post-implantation of new DES with biodegradable polymer. The aim of our study was to compare the local endothelial function assessed by exercise induced coronary vasomotion after implantation of a biolimus A9-eluting stent with biodegradable polymer (BES) with an everolimus-eluting stent with durable polymer (EES). Methods: Coronary vasomotion was evaluated with quantitative coronary angiography at rest and during supine bicycle exercise in nine patients with EES and thirteen patients with BES, 16 months after stent implantation. Mean luminal diameter of the stent, peristent segments, and of a control vessel were determined at rest, during exercise, and after the administration of nitroglycerine. Results: The control vessel showed exercise-induced vasodilatation in both groups (EES: + 6.4 ± 5.5%, p = 0.07; BES: + 7.8 ± 10.1%, p = 0.07). Vasomotion in the stented vessel segment was abolished. There was exercise-induced vasoconstriction in both groups in the segments proximal (EES: − 9.6 ± 4.5%; p = 0.03; BES: − 4.3 ± 5.4%, p = 0.02) and distal to the stent (EES: − 3.2 ± 9.3%; p = 0.41, BES − 8.6 ± 8.0%, p < 0.01). Sublingual nitroglycerin was associated with maximal vasodilatation of the peristent segments inAbstract: Background: Drug-eluting stents (DES) have been associated with local endothelial dysfunction in the segments proximal and distal to the stent (peristent segments) and increased thrombotic risk in long term follow-up. Little data exists on endothelial function post-implantation of new DES with biodegradable polymer. The aim of our study was to compare the local endothelial function assessed by exercise induced coronary vasomotion after implantation of a biolimus A9-eluting stent with biodegradable polymer (BES) with an everolimus-eluting stent with durable polymer (EES). Methods: Coronary vasomotion was evaluated with quantitative coronary angiography at rest and during supine bicycle exercise in nine patients with EES and thirteen patients with BES, 16 months after stent implantation. Mean luminal diameter of the stent, peristent segments, and of a control vessel were determined at rest, during exercise, and after the administration of nitroglycerine. Results: The control vessel showed exercise-induced vasodilatation in both groups (EES: + 6.4 ± 5.5%, p = 0.07; BES: + 7.8 ± 10.1%, p = 0.07). Vasomotion in the stented vessel segment was abolished. There was exercise-induced vasoconstriction in both groups in the segments proximal (EES: − 9.6 ± 4.5%; p = 0.03; BES: − 4.3 ± 5.4%, p = 0.02) and distal to the stent (EES: − 3.2 ± 9.3%; p = 0.41, BES − 8.6 ± 8.0%, p < 0.01). Sublingual nitroglycerin was associated with maximal vasodilatation of the peristent segments in both groups. Conclusion: Alike DES with durable polymer, stents with a biodegradable polymer are associated with exercise-induced paradoxical coronary vasoconstriction of the peristent segments. This data suggests that endothelial dysfunction after DES implantation is not primarily caused by the durability of the polymer coating. … (more)
- Is Part Of:
- International journal of cardiology. Volume 202(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 202(2016)
- Issue Display:
- Volume 202, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 202
- Issue:
- 2016
- Issue Sort Value:
- 2016-0202-2016-0000
- Page Start:
- 525
- Page End:
- 531
- Publication Date:
- 2016-01-01
- Subjects:
- Biolimus-eluting stent -- Everolimus-eluting stent -- Coronary artery disease -- Endothelial function
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2015.09.085 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7381.xml