Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations. (January 2017)
- Record Type:
- Journal Article
- Title:
- Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations. (January 2017)
- Main Title:
- Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations
- Authors:
- Holt, Eva
Bohlin-Nizzetto, Pernilla
Borůvková, Jana
Harner, Tom
Kalina, Jiří
Melymuk, Lisa
Klánová, Jana - Abstract:
- Abstract: Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate ( R s ) or to calculate air concentrations ( C air ) from PUF-PAS measurements for SVOCs. C air was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. C air were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: R s, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted R s ). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except forAbstract: Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate ( R s ) or to calculate air concentrations ( C air ) from PUF-PAS measurements for SVOCs. C air was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. C air were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: R s, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted R s ). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except for the particle-phase polycyclic aromatic hydrocarbons (PAHs). Underestimation of PUF-derived air concentrations for particle-phase PAHs was attributed to a potential overestimation of the particle infiltration into the PUF-PAS chamber and underestimation of the particle bound fraction of PAHs. Graphical abstract: Highlights: Air concentrations ( C air ) were calculated using long-term passive sampler monitoring. C air for gas-phase SVOCs were within 2–3 times of active air sampler measurements. C air for particle-phase PAHs were up to 23 time less than active air measurements. Particle infiltration into the passive sampler adds uncertainty to C air but is not well understood. Estimation of particle-bound fraction of PAHs could contribute to C air uncertainty. Abstract : Average PUF-PAS-derived air concentrations were generally within 2 times and less than 10 times AAS measurements for gas-phase and particle-phase SVOCs, respectively. … (more)
- Is Part Of:
- Environmental pollution. Volume 220:Part B(2017)
- Journal:
- Environmental pollution
- Issue:
- Volume 220:Part B(2017)
- Issue Display:
- Volume 220, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 220
- Issue:
- 2
- Issue Sort Value:
- 2017-0220-0002-0000
- Page Start:
- 1100
- Page End:
- 1111
- Publication Date:
- 2017-01
- Subjects:
- Passive sampling -- Air monitoring -- Data interpretation -- Data comparability -- Semi-volatile organic compounds (SVOCs)
Pollution -- Periodicals
Pollution -- Environmental aspects -- Periodicals
Environmental Pollution -- Periodicals
Pollution -- Périodiques
Pollution -- Aspect de l'environnement -- Périodiques
Pollution -- Effets physiologiques -- Périodiques
Pollution
Pollution -- Environmental aspects
Periodicals
Electronic journals
363.73 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02697491 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.envpol.2016.11.030 ↗
- Languages:
- English
- ISSNs:
- 0269-7491
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.539000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7386.xml