Moisture in Multi-Layer Windows. (November 2015)
- Record Type:
- Journal Article
- Title:
- Moisture in Multi-Layer Windows. (November 2015)
- Main Title:
- Moisture in Multi-Layer Windows
- Authors:
- Asphaug, Silje
Time, Berit
Uvsløkk, Sivert
Plsek, Dalibor
Gustavsen, Arild - Abstract:
- Abstract: There is an increasing interest in development of coupled multi-layer window structures. This is to optimize thermal properties and to develop systems with a better climate protected solar shading system. The risk of condensation on the inside of the exterior glass layer in a multi-layer window structure might be a challenge and is often questioned. The risk of condensation will depend on both window properties and indoor and outdoor climate conditions. The air gap between the inner and outer part have to be ventilated with outdoor air to give the window a "drying out" capacity. The U-value of the window and the moisture condition in the air gap both depend on the ventilation of the air gap. Reducing the ventilation improves the U-value, but increases the time of desiccation.Net long-wave radiation from the glass surface to the atmosphere during cloudless night-time will cause exterior glass temperatures lower than the outdoor air temperature, and hence increase the risk of condensation on both sides of the exterior glass. The aim of this work has been to assess for which climate conditions there will be a risk of condensation on the exterior glass layer and what might be the optimal ventilation of the outermost air gap. Simulations of the temperature on the exterior surface of the glazing including the long-wave radiation during night- time have been done and compared to measurements. An assessment has been made studying the risk of condensation and the drying outAbstract: There is an increasing interest in development of coupled multi-layer window structures. This is to optimize thermal properties and to develop systems with a better climate protected solar shading system. The risk of condensation on the inside of the exterior glass layer in a multi-layer window structure might be a challenge and is often questioned. The risk of condensation will depend on both window properties and indoor and outdoor climate conditions. The air gap between the inner and outer part have to be ventilated with outdoor air to give the window a "drying out" capacity. The U-value of the window and the moisture condition in the air gap both depend on the ventilation of the air gap. Reducing the ventilation improves the U-value, but increases the time of desiccation.Net long-wave radiation from the glass surface to the atmosphere during cloudless night-time will cause exterior glass temperatures lower than the outdoor air temperature, and hence increase the risk of condensation on both sides of the exterior glass. The aim of this work has been to assess for which climate conditions there will be a risk of condensation on the exterior glass layer and what might be the optimal ventilation of the outermost air gap. Simulations of the temperature on the exterior surface of the glazing including the long-wave radiation during night- time have been done and compared to measurements. An assessment has been made studying the risk of condensation and the drying out rate for climate conditions for two locations in Germany. A spreadsheet-based model calculating the U-value of a multilayer glazing unit according to ISO 15099[1] has been further developed including airflow from exterior openings through the air gap. … (more)
- Is Part Of:
- Energy procedia. Volume 78(2015)
- Journal:
- Energy procedia
- Issue:
- Volume 78(2015)
- Issue Display:
- Volume 78, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 78
- Issue:
- 2015
- Issue Sort Value:
- 2015-0078-2015-0000
- Page Start:
- 2482
- Page End:
- 2487
- Publication Date:
- 2015-11
- Subjects:
- Multy-Layer Windows -- Moisture -- Condensation -- Long-wave radiation
Power resources -- Congresses
Power resources -- Periodicals
Power resources
Conference proceedings
Periodicals
333.7905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18766102 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.egypro.2015.11.233 ↗
- Languages:
- English
- ISSNs:
- 1876-6102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.729700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7393.xml