Kiwi omnicup handheld versus Mityvac M-style conventional vacuum system: a retrospective observational study. (2nd December 2018)
- Record Type:
- Journal Article
- Title:
- Kiwi omnicup handheld versus Mityvac M-style conventional vacuum system: a retrospective observational study. (2nd December 2018)
- Main Title:
- Kiwi omnicup handheld versus Mityvac M-style conventional vacuum system: a retrospective observational study
- Authors:
- Weissbach, Tal
Hag-Yahia, Nasreen
Ovadia, Michal
Tzadikevitch Geffen, Keren
Weitzner, Omer
Biron-Shental, Tal - Abstract:
- Abstract: Introduction: To improve the choice of vacuum-assisted delivery (VAD) system, we compared the outcomes of Kiwi handheld system and Mityvac M-style conventional system (both use disposable plastic cups). Materials and methods: Retrospective observational study with data collection from electronic medical records. The study was conducted at a tertiary medical center, with approximately 7000 deliveries annually. Categorical and continuous variables were analyzed using chi-square test and t-test, respectively. p value < .05 was considered significant. The main outcomes assessed were the overall failure rate of each system, failure rates for occipito-anterior (OA) versus occipito-transverse/occipito-anterior (OT/OP) positions, +1 versus +2 fetal stations, and early maternal/neonatal outcomes. Results: During a 10-month period, there were 507 (8.4%) attempted VADs, 36 failed (7.1%), and eight (1.5%) converted to cesarean section. Of these, 364 were Kiwi-assisted and 143 Mityvac-assisted. Background characteristics were similar. The handheld system had more failures overall (9.6 versus 0.7%), at OA (7.6 versus 0.9%), and non-OA positions (17.3% versus none), at +1 (13.25 versus 0.96%) and at +2/3 stations (6.1% versus none), than the conventional system did, respectively. There was a higher rate of early post-partum hemorrhage (15.3 versus 7.4%) in the conventional group. Both systems had similar rates of third/fourth degree perineal tears, shoulder dystocia and adverseAbstract: Introduction: To improve the choice of vacuum-assisted delivery (VAD) system, we compared the outcomes of Kiwi handheld system and Mityvac M-style conventional system (both use disposable plastic cups). Materials and methods: Retrospective observational study with data collection from electronic medical records. The study was conducted at a tertiary medical center, with approximately 7000 deliveries annually. Categorical and continuous variables were analyzed using chi-square test and t-test, respectively. p value < .05 was considered significant. The main outcomes assessed were the overall failure rate of each system, failure rates for occipito-anterior (OA) versus occipito-transverse/occipito-anterior (OT/OP) positions, +1 versus +2 fetal stations, and early maternal/neonatal outcomes. Results: During a 10-month period, there were 507 (8.4%) attempted VADs, 36 failed (7.1%), and eight (1.5%) converted to cesarean section. Of these, 364 were Kiwi-assisted and 143 Mityvac-assisted. Background characteristics were similar. The handheld system had more failures overall (9.6 versus 0.7%), at OA (7.6 versus 0.9%), and non-OA positions (17.3% versus none), at +1 (13.25 versus 0.96%) and at +2/3 stations (6.1% versus none), than the conventional system did, respectively. There was a higher rate of early post-partum hemorrhage (15.3 versus 7.4%) in the conventional group. Both systems had similar rates of third/fourth degree perineal tears, shoulder dystocia and adverse neonatal outcomes. Conclusions: Our results suggest more failures with Kiwi compared to Mityvac, overall and at any fetal position/station, without a significant difference in adverse outcome profile. … (more)
- Is Part Of:
- Journal of maternal-fetal & neonatal medicine. Volume 31:Number 23(2018)
- Journal:
- Journal of maternal-fetal & neonatal medicine
- Issue:
- Volume 31:Number 23(2018)
- Issue Display:
- Volume 31, Issue 23 (2018)
- Year:
- 2018
- Volume:
- 31
- Issue:
- 23
- Issue Sort Value:
- 2018-0031-0023-0000
- Page Start:
- 3178
- Page End:
- 3182
- Publication Date:
- 2018-12-02
- Subjects:
- Conventional vacuum system -- hand-held vacuum system -- Kiwi omnicup -- M-style Mityvac cup -- vacuum assisted delivery
Obstetrics -- Periodicals
Perinatology -- Periodicals
Infants (Newborn) -- Diseases -- Periodicals
Neonatology -- Periodicals
618.2 - Journal URLs:
- http://informahealthcare.com/loi/jmf ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/14767058.2017.1366443 ↗
- Languages:
- English
- ISSNs:
- 1476-7058
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.332000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7366.xml