An alpha particle detector based on a GPS mosaic scintillator plate for continuous air monitoring in plutonium handling facilities. (October 2016)
- Record Type:
- Journal Article
- Title:
- An alpha particle detector based on a GPS mosaic scintillator plate for continuous air monitoring in plutonium handling facilities. (October 2016)
- Main Title:
- An alpha particle detector based on a GPS mosaic scintillator plate for continuous air monitoring in plutonium handling facilities
- Authors:
- Kaneko, Junichi H.
Izaki, Kenji
Toui, Kouhei
Shimaoka, Takehiro
Morishita, Yuki
Tsubota, Youichi
Higuchi, Mikio - Abstract:
- Abstract: An alpha particle detector was developed for continuous air monitoring of radioactive contamination in working chambers at plutonium handling facilities. A 5-cm-square Gd2 Si2 O7 :Ce (cerium-doped gadolinium pyro-silicate, GPS:Ce) mosaic scintillator plate for alpha particle measurements was fabricated from GPS single-crystal grains of around 550 μm diameter; the GPS grains were made of a GPS polycrystalline body grown using a top seeded solution method. The scintillator layer thickness was approximately 100 μm. The surface filling rate of the GPS grains was ca. 62%. To suppress the influence of non-uniformity of pulse heights of a photomultiplier tube, a central part of ∅ 40 mm of a 76-mm-diameter photomultiplier tube was used. In addition, 3 mm thick high-transmission glass was used as a substrate of the scintillator plate. The detector achieved energy resolution of 13% for 5.5 MeV alpha particles, detection efficiency of 61% and a radon progeny nuclide reduction ratio of 64.5%. A new alpha particle detector was developed to achieve a high radon progeny nuclide reduction ratio approaching that of a silicon semiconductor detector, with high resistance to electromagnetic noise and corrosion. Highlights: An alpha particle detector was developed for continuous air monitoring. The detector comprises a mosaic scintillator plate and a photomultiplier tube. A 5-cm-square GPS mosaic scintillator plate was fabricated. Its respective energy resolution and detectionAbstract: An alpha particle detector was developed for continuous air monitoring of radioactive contamination in working chambers at plutonium handling facilities. A 5-cm-square Gd2 Si2 O7 :Ce (cerium-doped gadolinium pyro-silicate, GPS:Ce) mosaic scintillator plate for alpha particle measurements was fabricated from GPS single-crystal grains of around 550 μm diameter; the GPS grains were made of a GPS polycrystalline body grown using a top seeded solution method. The scintillator layer thickness was approximately 100 μm. The surface filling rate of the GPS grains was ca. 62%. To suppress the influence of non-uniformity of pulse heights of a photomultiplier tube, a central part of ∅ 40 mm of a 76-mm-diameter photomultiplier tube was used. In addition, 3 mm thick high-transmission glass was used as a substrate of the scintillator plate. The detector achieved energy resolution of 13% for 5.5 MeV alpha particles, detection efficiency of 61% and a radon progeny nuclide reduction ratio of 64.5%. A new alpha particle detector was developed to achieve a high radon progeny nuclide reduction ratio approaching that of a silicon semiconductor detector, with high resistance to electromagnetic noise and corrosion. Highlights: An alpha particle detector was developed for continuous air monitoring. The detector comprises a mosaic scintillator plate and a photomultiplier tube. A 5-cm-square GPS mosaic scintillator plate was fabricated. Its respective energy resolution and detection efficiency were 13 and 61%. The radon progeny nuclide reduction ratio of the developed detector was 64.5%. … (more)
- Is Part Of:
- Radiation measurements. Volume 93(2016:Oct.)
- Journal:
- Radiation measurements
- Issue:
- Volume 93(2016:Oct.)
- Issue Display:
- Volume 93 (2016)
- Year:
- 2016
- Volume:
- 93
- Issue Sort Value:
- 2016-0093-0000-0000
- Page Start:
- 13
- Page End:
- 19
- Publication Date:
- 2016-10
- Subjects:
- Continuous air monitoring -- Plutonium handling facility -- Alpha particle detector -- Mosaic scintillator plate -- Gd2Si2O7:Ce (GPS)
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2016.07.006 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7372.xml