PP.17.04: COMPARISON OF AN IN-PHARMACY AUTOMATED BLOOD PRESSURE KIOSK TO DAYTIME AMBULATORY BLOOD PRESSURE IN HYPERTENSIVE SUBJECTS. (June 2015)
- Record Type:
- Journal Article
- Title:
- PP.17.04: COMPARISON OF AN IN-PHARMACY AUTOMATED BLOOD PRESSURE KIOSK TO DAYTIME AMBULATORY BLOOD PRESSURE IN HYPERTENSIVE SUBJECTS. (June 2015)
- Main Title:
- PP.17.04
- Authors:
- Padwal, R.
Townsend, R.
Trudeau, L.
Hamilton, P.
Gelfer, M. - Abstract:
- Abstract : Objective: Millions of readings are taken from in-pharmacy kiosks daily in North America but information on the accuracy of these kiosks is limited. We sought to compare serial readings from an in-pharmacy automated BP kiosk to mean daytime ambulatory BP. Design and method: 100 community-dwelling adults with hypertension underwent: a. three baseline automated office readings; b. three in-pharmacy kiosk readings on each of four visits (12 total) using the PharmaSmart PS-2000 kiosk; and c. 24-hour ambulatory BP monitoring between in-pharmacy visits two and three. The primary analysis compared the in-pharmacy device to daytime ambulatory readings. A secondary analysis compared the baseline automated office device to daytime ambulatory blood pressure. Paired t-tests, Bland-Altman plots and Pearson's correlation coefficients were used for analysis. Results: Mean BPs were 137.8 ± 13.7/81.9 ± 12.2 mmHg for in-pharmacy and 135.5 ± 11.7/79.7 ± 10.0 mmHg for daytime ambulatory (difference of 2.3 ± 9.5/2.2 ± 6.9 mmHg [p = <0.05]). Bland-Altman plots depicted a high degree of blood pressure variability but did not show clinically important systematic BP differences. With ambulatory BP as the reference standard, in-pharmacy device results were similar to automated office. Correlation with daytime ambulatory BP was 0.73 for SBP and 0.83 for DBP (p < 0.0001 for both) for the in-pharmacy device and, 0.58 for SBP and 0.66 for DBP (p < 0.0001 for both) for the automated device.Abstract : Objective: Millions of readings are taken from in-pharmacy kiosks daily in North America but information on the accuracy of these kiosks is limited. We sought to compare serial readings from an in-pharmacy automated BP kiosk to mean daytime ambulatory BP. Design and method: 100 community-dwelling adults with hypertension underwent: a. three baseline automated office readings; b. three in-pharmacy kiosk readings on each of four visits (12 total) using the PharmaSmart PS-2000 kiosk; and c. 24-hour ambulatory BP monitoring between in-pharmacy visits two and three. The primary analysis compared the in-pharmacy device to daytime ambulatory readings. A secondary analysis compared the baseline automated office device to daytime ambulatory blood pressure. Paired t-tests, Bland-Altman plots and Pearson's correlation coefficients were used for analysis. Results: Mean BPs were 137.8 ± 13.7/81.9 ± 12.2 mmHg for in-pharmacy and 135.5 ± 11.7/79.7 ± 10.0 mmHg for daytime ambulatory (difference of 2.3 ± 9.5/2.2 ± 6.9 mmHg [p = <0.05]). Bland-Altman plots depicted a high degree of blood pressure variability but did not show clinically important systematic BP differences. With ambulatory BP as the reference standard, in-pharmacy device results were similar to automated office. Correlation with daytime ambulatory BP was 0.73 for SBP and 0.83 for DBP (p < 0.0001 for both) for the in-pharmacy device and, 0.58 for SBP and 0.66 for DBP (p < 0.0001 for both) for the automated device. Conclusions: The PharmaSmart PS-2000 closely approximated mean daytime ambulatory BP, supporting the use of serial readings from this device in the assessment of BP. … (more)
- Is Part Of:
- Journal of hypertension. Volume 33(2015)Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 33(2015)Supplement 1
- Issue Display:
- Volume 33, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2015-0033-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-06
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000468227.86540.ad ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7360.xml