Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing. Issue 1 (January 2017)
- Record Type:
- Journal Article
- Title:
- Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing. Issue 1 (January 2017)
- Main Title:
- Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing
- Authors:
- Deng, Gaofeng
Li, Zenghe
Wang, Zhichao
Gao, Jubao
Xu, Zhaowei
Li, Jiandong
Wang, Zhiyong - Abstract:
- Indoor and outdoor particulate matter 2.5 (PM2.5 ) concentrations were monitored in seven sampling sites: basketball stadium, hotel, shopping centre, research centre, commercial office, apartment building and villa, to determine the indoor and outdoor relationship of PM2.5 mass concentration in the central area of Beijing from February 2014 to March 2014. The influence of four types of ventilation systems on indoor to outdoor (I/O) ratio of PM2.5 concentration was evaluated. The measured results show that the mean I/O ratio of the seven locations was 0.36 when the outdoor PM2.5 concentration was more than 150 µg/m 3, and 1.1 when the outdoor PM2.5 concentration was less than 100 µg/m 3, which implies that people's activities could be the most likely factor rather than outdoor sources for elevated indoor PM2.5 levels. The average I/O ratio was 0.69 for public buildings and 0.94 for residential homes, which illustrates that indoor PM2.5 concentrations could be dominated by outdoor sources for residential homes. Approximately 90% of the outdoor particles were removed in public buildings equipped with fan-coil unit with air cleaning plus fresh air system. The results demonstrate the need to improve indoor air quality by using a proper ventilation system with air cleaning.
- Is Part Of:
- Indoor + built environment. Volume 26:Issue 1(2017)
- Journal:
- Indoor + built environment
- Issue:
- Volume 26:Issue 1(2017)
- Issue Display:
- Volume 26, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 26
- Issue:
- 1
- Issue Sort Value:
- 2017-0026-0001-0000
- Page Start:
- 60
- Page End:
- 68
- Publication Date:
- 2017-01
- Subjects:
- Indoor air quality -- Particulate matter 2.5 -- Public building -- Residential home -- Ventilation systems -- Air cleaning unit -- Indoor to outdoor ratio
Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Buildings -- Environmental engineering -- Periodicals
Environmental health -- Periodicals
613.5 - Journal URLs:
- http://ibe.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://firstsearch.oclc.org ↗
http://www.ingenta.com/isis/browsing/AllIssues/ingenta;jsessionid=2uxluqljhi7q.crescent?journal=pubinfobike://sage/ibe ↗ - DOI:
- 10.1177/1420326X15604349 ↗
- Languages:
- English
- ISSNs:
- 1420-326X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7362.xml