Comparison of the buccal mucosal bleeding time in dogs using 3 different‐sized lancet devices. (16th October 2013)
- Record Type:
- Journal Article
- Title:
- Comparison of the buccal mucosal bleeding time in dogs using 3 different‐sized lancet devices. (16th October 2013)
- Main Title:
- Comparison of the buccal mucosal bleeding time in dogs using 3 different‐sized lancet devices
- Authors:
- Aumann, Marcel
Rossi, Valentina
Le Boedec, Kevin
Diquélou, Armelle - Abstract:
- Abstract : Background: The buccal mucosal bleeding time (BMBT) evaluates primary hemostasis in vivo. Three different‐sized lancet devices designed for people, Adult (A), Junior (J), and Newborn (N), can be used to perform the BMBT in dogs. Objectives: The aim was to compare BMBT using 3 different‐sized human lancet devices in dogs with varying platelet counts and hematocrits. Methods: The BMBT was measured in 46 client‐owned dogs (2 healthy, 44 suffering from various disorders) with varying platelet (Plt) counts and hematocrits, using the 3 devices successively in each dog, in a randomly determined order, over a 10‐ to 30‐minute period. Statistical analysis (ANOVA, Mann–Whitney U ‐test) was performed using commercial software. Results: BMBTs were significantly different between devices ( P < .00001), and shorter with devices N and J compared with device A ( P < .01). The BMBT was prolonged (> 210 s) in 10 dogs with device A and in 7 dogs each with devices J and N, respectively. Sixteen dogs had a Plt count < 200 × 10 9 /L (Reference interval 200–500 × 10 9 /L). Nine of these dogs had prolonged BMBT with device A, and 6 dogs with device J and device N, respectively. BMBT was longer in thrombocytopenic dogs with devices A and J ( P < .016). Anemia without thrombocytopenia did not affect BMBT with any device. Conclusions: The BMBT is influenced by the size of the used device, with A resulting in the longest BMBT. Therefore, the type of device used to obtain the BMBT has toAbstract : Background: The buccal mucosal bleeding time (BMBT) evaluates primary hemostasis in vivo. Three different‐sized lancet devices designed for people, Adult (A), Junior (J), and Newborn (N), can be used to perform the BMBT in dogs. Objectives: The aim was to compare BMBT using 3 different‐sized human lancet devices in dogs with varying platelet counts and hematocrits. Methods: The BMBT was measured in 46 client‐owned dogs (2 healthy, 44 suffering from various disorders) with varying platelet (Plt) counts and hematocrits, using the 3 devices successively in each dog, in a randomly determined order, over a 10‐ to 30‐minute period. Statistical analysis (ANOVA, Mann–Whitney U ‐test) was performed using commercial software. Results: BMBTs were significantly different between devices ( P < .00001), and shorter with devices N and J compared with device A ( P < .01). The BMBT was prolonged (> 210 s) in 10 dogs with device A and in 7 dogs each with devices J and N, respectively. Sixteen dogs had a Plt count < 200 × 10 9 /L (Reference interval 200–500 × 10 9 /L). Nine of these dogs had prolonged BMBT with device A, and 6 dogs with device J and device N, respectively. BMBT was longer in thrombocytopenic dogs with devices A and J ( P < .016). Anemia without thrombocytopenia did not affect BMBT with any device. Conclusions: The BMBT is influenced by the size of the used device, with A resulting in the longest BMBT. Therefore, the type of device used to obtain the BMBT has to be specified for standardized results. … (more)
- Is Part Of:
- Veterinary clinical pathology. Volume 42:Number 4(2013)
- Journal:
- Veterinary clinical pathology
- Issue:
- Volume 42:Number 4(2013)
- Issue Display:
- Volume 42, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2013-0042-0004-0000
- Page Start:
- 451
- Page End:
- 457
- Publication Date:
- 2013-10-16
- Subjects:
- Dogs -- hemorrhage -- mucosa -- platelets -- primary hemostasis
Veterinary pathology -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/vcp.12087 ↗
- Languages:
- English
- ISSNs:
- 0275-6382
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9227.015500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7322.xml