Significance and Reliability of MARD for the Accuracy of CGM Systems. (January 2017)
- Record Type:
- Journal Article
- Title:
- Significance and Reliability of MARD for the Accuracy of CGM Systems. (January 2017)
- Main Title:
- Significance and Reliability of MARD for the Accuracy of CGM Systems
- Authors:
- Reiterer, Florian
Polterauer, Philipp
Schoemaker, Michael
Schmelzeisen-Redecker, Guenther
Freckmann, Guido
Heinemann, Lutz
del Re, Luigi - Abstract:
- Background: There is a need to assess the accuracy of continuous glucose monitoring (CGM) systems for several uses. Mean absolute relative difference (MARD) is the measure of choice for this. Unfortunately, it is frequently overlooked that MARD values computed with data acquired during clinical studies do not reflect the accuracy of the CGM system only, but are strongly influenced by the design of the study. Thus, published MARD values must be understood not as precise values but as indications with some uncertainty. Data and Methods: Data from a recent clinical trial, Monte Carlo simulations, and assumptions about the error distribution of the reference measurements have been used to determine the confidence region of MARD as a function of the number and the accuracy of the reference measurements. Results: The uncertainty of the computed MARD values can be quantified by a newly introduced MARD reliability index (MRI), which independently mirrors the reliability of the evaluation. Thus MARD conveys information on the accuracy of the CGM system, while MRI conveys information on the uncertainty of the computed MARD values. Conclusions: MARD values from clinical studies should not be used blindly but the reliability of the evaluation should be considered as well. Furthermore, it should not be ignored that MARD does not take into account the key feature of CGM sensors, the frequency of the measurements. Additional metrics, such as precision absolute relative difference (PARD)Background: There is a need to assess the accuracy of continuous glucose monitoring (CGM) systems for several uses. Mean absolute relative difference (MARD) is the measure of choice for this. Unfortunately, it is frequently overlooked that MARD values computed with data acquired during clinical studies do not reflect the accuracy of the CGM system only, but are strongly influenced by the design of the study. Thus, published MARD values must be understood not as precise values but as indications with some uncertainty. Data and Methods: Data from a recent clinical trial, Monte Carlo simulations, and assumptions about the error distribution of the reference measurements have been used to determine the confidence region of MARD as a function of the number and the accuracy of the reference measurements. Results: The uncertainty of the computed MARD values can be quantified by a newly introduced MARD reliability index (MRI), which independently mirrors the reliability of the evaluation. Thus MARD conveys information on the accuracy of the CGM system, while MRI conveys information on the uncertainty of the computed MARD values. Conclusions: MARD values from clinical studies should not be used blindly but the reliability of the evaluation should be considered as well. Furthermore, it should not be ignored that MARD does not take into account the key feature of CGM sensors, the frequency of the measurements. Additional metrics, such as precision absolute relative difference (PARD) should be used as well to obtain a better evaluation of the CGM performance for specific uses, for example, for artificial pancreas. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 11:Number 1(2017:Jan.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 11:Number 1(2017:Jan.)
- Issue Display:
- Volume 11, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2017-0011-0001-0000
- Page Start:
- 59
- Page End:
- 67
- Publication Date:
- 2017-01
- Subjects:
- continuous glucose monitoring -- diabetes therapy -- quality of measurement -- glucose measurement -- blood glucose
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296816662047 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7301.xml