Comprehensive Multicenter Study of the Common Isthmus in Post–Atrial Fibrillation Ablation Multiple-Loop Atrial Tachycardia. (June 2018)
- Record Type:
- Journal Article
- Title:
- Comprehensive Multicenter Study of the Common Isthmus in Post–Atrial Fibrillation Ablation Multiple-Loop Atrial Tachycardia. (June 2018)
- Main Title:
- Comprehensive Multicenter Study of the Common Isthmus in Post–Atrial Fibrillation Ablation Multiple-Loop Atrial Tachycardia
- Authors:
- Takigawa, Masateru
Derval, Nicolas
Maury, Philippe
Martin, Ruairidh
Denis, Arnaud
Miyazaki, Shinsuke
Yamashita, Seigo
Frontera, Antonio
Vlachos, Konstantinos
Kitamura, Takeshi
Cheniti, Ghassen
Massoullieé, Greégoire
Thompson, Nathaniel
Martin, Claire A.
Wolf, Michael
Pillois, Xavier
Duchateau, Josselin
Klotz, Nicolas
Duparc, Alexandre
Rollin, Anne
Pambrun, Thomas
Sacher, Frédéric
Cochet, Hubert
Hocini, Mélèze
Haiïssaguerre, Michel
Jaiïs, Pierre - Abstract:
- Abstract : Background: Characteristics of multiple-loop atrial tachycardia (AT) circuits have never precisely examined. Methods: In 193 consecutive post–atrial fibrillation ablation patients with AT, 44 multiple-loop ATs including 42 dual-loop AT and 2 triple-loop AT in 41 (21.2%) were diagnosed with the high-resolution mapping system and analyzed off-line. Results: In dual-loop ATs, 3 types were identified: type M, a combination of 2 anatomic macroreentrant ATs (AMATs) in 19 (43.2%); type MN, with 1 AMAT and 1 non-AMAT in 12 (27.3%); and type N with 2 non-AMATs in 11 (25.0%). The remaining 2 triple-loop ATs (4.5%) were a combination of perimitral-, roof-dependent-, and non-AMAT. At least 1 AMAT was included in 33 (75.0%), and 1 non-AMAT in 25 (56.8%). Of the ATs with at least 1 non-AMAT circuit, a pulmonary vein formed part of the circuit in 16/25 (64.0%). The length of the common isthmus was 3.6±1.4 cm in type M, 1.6±0.7 cm in type MN, and 1.1±0.7 cm in type N ( P <0.0001). The area of the common isthmus was 12.92±7.68, 2.46±1.53, and 0.90±0.81 cm 2, in Type M, MN, and N ( P <0.0001). The narrowest width of the common isthmus was 1.8±0.7 cm, 1.1±0.3 cm, and 0.7±0.3 cm in type M, MN, and N ( P <0.0001), respectively. The electrograms in the common isthmus showed longer duration and lower voltage in type N, type MN, and type M (duration: 106±25 ms, 87±27 ms, and 69±27 ms; P =0.006; and voltage: 0.06±0.02 mV, 0.22±0.21 mV, and 0.57±0.50 mV; P <0.0001), respectively.Abstract : Background: Characteristics of multiple-loop atrial tachycardia (AT) circuits have never precisely examined. Methods: In 193 consecutive post–atrial fibrillation ablation patients with AT, 44 multiple-loop ATs including 42 dual-loop AT and 2 triple-loop AT in 41 (21.2%) were diagnosed with the high-resolution mapping system and analyzed off-line. Results: In dual-loop ATs, 3 types were identified: type M, a combination of 2 anatomic macroreentrant ATs (AMATs) in 19 (43.2%); type MN, with 1 AMAT and 1 non-AMAT in 12 (27.3%); and type N with 2 non-AMATs in 11 (25.0%). The remaining 2 triple-loop ATs (4.5%) were a combination of perimitral-, roof-dependent-, and non-AMAT. At least 1 AMAT was included in 33 (75.0%), and 1 non-AMAT in 25 (56.8%). Of the ATs with at least 1 non-AMAT circuit, a pulmonary vein formed part of the circuit in 16/25 (64.0%). The length of the common isthmus was 3.6±1.4 cm in type M, 1.6±0.7 cm in type MN, and 1.1±0.7 cm in type N ( P <0.0001). The area of the common isthmus was 12.92±7.68, 2.46±1.53, and 0.90±0.81 cm 2, in Type M, MN, and N ( P <0.0001). The narrowest width of the common isthmus was 1.8±0.7 cm, 1.1±0.3 cm, and 0.7±0.3 cm in type M, MN, and N ( P <0.0001), respectively. The electrograms in the common isthmus showed longer duration and lower voltage in type N, type MN, and type M (duration: 106±25 ms, 87±27 ms, and 69±27 ms; P =0.006; and voltage: 0.06±0.02 mV, 0.22±0.21 mV, and 0.57±0.50 mV; P <0.0001), respectively. Conclusions: Multiple-loop ATs are complex, frequently including anatomic circuits. They have specific characteristics determined by the combination of AMAT and non-AMAT. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 11:Number 6(2018)
- Journal:
- Circulation
- Issue:
- Volume 11:Number 6(2018)
- Issue Display:
- Volume 11, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 11
- Issue:
- 6
- Issue Sort Value:
- 2018-0011-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-06
- Subjects:
- atrial fibrillation -- catheter ablation -- conscious sedation -- pulmonary veins -- tachycardia
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.117.006019 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7268.xml