[OA148] A multi-center dosimetry study to evaluate imaging dose from Elekta XVI and varian OBI KV-CONE beam CT systems to cardiovascular implantable electronic devices (CIEDS). (August 2018)
- Record Type:
- Journal Article
- Title:
- [OA148] A multi-center dosimetry study to evaluate imaging dose from Elekta XVI and varian OBI KV-CONE beam CT systems to cardiovascular implantable electronic devices (CIEDS). (August 2018)
- Main Title:
- [OA148] A multi-center dosimetry study to evaluate imaging dose from Elekta XVI and varian OBI KV-CONE beam CT systems to cardiovascular implantable electronic devices (CIEDS)
- Authors:
- Aslian, Hossein
Delana, Anna
kaiser, Stefano Ren
Moretti, Eugenia
Foti, Claudio
Bregant, Paola
Denaro, Mario De
Longo, Francesco
Severgnini, Mara - Abstract:
- Abstract : Purpose: By increasing the use of daily CBCT, additional delivered imaging dose to the patient became a matter of concern. This can also raise concerns about patients with CIEDs since accumulated dose to these devices highly needs to be limited. The aim of this study is to investigate the imaging dose to the CIEDs from Elekta XVI and Varian OBI kV-CBCT systems performed by a multi-institutional study. Methods: Four geographically separated centers with different CBCT imaging systems and three different dosimetric measurement methods including Gafchromic films, metal-oxide-semiconductor field-effect transistor (MOSFET) and thermoluminescence dosimeters (TLDs) participated in this multi-center study. At each center an anthropomorphic phantom (Alderson RANDO phantom) was used and the CIED was placed in the alderson's left clavicular region using the same setup. The dosimeter was fixed on top of the device over which a 1-cm thick bolus was used to simulate patient's skin. Different standard CBCT-imaging protocols which are commonly used in clinical practice of each center were applied namely, Head&Neck (HN), Chest, Thorax, Symmetry, Prostate and Pelvis. Results: The maximum values of imaging doses were found once CIEDs were inside the CBCT field. They were between the following values: HNS20 (XVI):2.57 mGy/100 mAs, Thorax (OBI):2.92 mGy/100 mAs, ChestM15-left (XVI): 1.52 mGy/100 mAs, Symmetry-left (XVI): 5.67 mGy/100 mAs. However, they received much lower dose onceAbstract : Purpose: By increasing the use of daily CBCT, additional delivered imaging dose to the patient became a matter of concern. This can also raise concerns about patients with CIEDs since accumulated dose to these devices highly needs to be limited. The aim of this study is to investigate the imaging dose to the CIEDs from Elekta XVI and Varian OBI kV-CBCT systems performed by a multi-institutional study. Methods: Four geographically separated centers with different CBCT imaging systems and three different dosimetric measurement methods including Gafchromic films, metal-oxide-semiconductor field-effect transistor (MOSFET) and thermoluminescence dosimeters (TLDs) participated in this multi-center study. At each center an anthropomorphic phantom (Alderson RANDO phantom) was used and the CIED was placed in the alderson's left clavicular region using the same setup. The dosimeter was fixed on top of the device over which a 1-cm thick bolus was used to simulate patient's skin. Different standard CBCT-imaging protocols which are commonly used in clinical practice of each center were applied namely, Head&Neck (HN), Chest, Thorax, Symmetry, Prostate and Pelvis. Results: The maximum values of imaging doses were found once CIEDs were inside the CBCT field. They were between the following values: HNS20 (XVI):2.57 mGy/100 mAs, Thorax (OBI):2.92 mGy/100 mAs, ChestM15-left (XVI): 1.52 mGy/100 mAs, Symmetry-left (XVI): 5.67 mGy/100 mAs. However, they received much lower dose once the CIEDs were not inside the field. Conclusion: This study shows that although imaging doses received by CIEDs outside the CBCT field is negligible, a special attention should be paid to this value when CIEDs are inside the CBCT field because daily use of CBCT can make a considerable contribution to the total dose received by CIED. Based on the obtained results, it is possible that in some protocol like symmetry total imaging dose to CIED in a 30-fraction reach as high as 50 cGy. Therefore in such cases, this additional imaging dose should not be ignored when classifying CIED patients into risk groups. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 56
- Page End:
- 57
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.220 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7292.xml