[P171] Quality control measurements for head and neck cancer patients with SHANE Phantom. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P171] Quality control measurements for head and neck cancer patients with SHANE Phantom. (August 2018)
- Main Title:
- [P171] Quality control measurements for head and neck cancer patients with SHANE Phantom
- Authors:
- Melles-Bencsik, Barbara
Mihály, Dalma
Tolvaj, Eniko˝
Nagy, Zoltán Takácsi
Major, Tibor
Polgár, Csaba
Pesznyák, Csilla - Abstract:
- Abstract : Purpose: To investigate irradiation techniques for simultaneous integrated boost (SIB) treatment of nasopharyngeal cancer (NPC) case in terms of organs at risk (OAR) toxicity and patient specific quality control (QC). This study is a part of an end-to-end audit programme for dose delivery using intensity modulated radiation therapy (IMRT). Methods: CIRS SHANE Phantom was used to create four different treatment plans for a NPC patient. SIB schedule prescribes 54 Gy, 60 Gy and 70 Gy in 30 fractions for elective nodes (both sides), involved nodes (right side) and primary nasopharynx respectively, using 1, 2 or 3 arcs RapidArc (RA) or 7 field Sliding Window (SW) techniques. Patient specific quality control measurements were performed using EPID. Varian Portal Dosimetry was used with local gamma analysis using 2%/2 mm and 3%/3 mm criteria with 10% threshold. Results: All plans met the criteria of dose to OARs: D2% of the spinal cord and the brainstem on average were 35 Gy and 35.5 Gy; mean dose of the left parotid on average was 22.9 Gy. Patient specific QC was performed without any interruption. MUs for 1, 2, 3 arcs and 7 field SW were 602, 706, 696 and 2447, respectively. Gamma analysis on EPID images gave 96.2%, 96.2%, 96.7%, 82.6% and 98, 8%, 98.9%, 99.3%, 92, 1% passing rate on average for 2%/ 2 mm and 3%/ 3 mm criteria, respectively. Conclusions: All treatment techniques are suitable for NPC irradiation with SIB in terms of OAR toxicity although RA with 2 or 3Abstract : Purpose: To investigate irradiation techniques for simultaneous integrated boost (SIB) treatment of nasopharyngeal cancer (NPC) case in terms of organs at risk (OAR) toxicity and patient specific quality control (QC). This study is a part of an end-to-end audit programme for dose delivery using intensity modulated radiation therapy (IMRT). Methods: CIRS SHANE Phantom was used to create four different treatment plans for a NPC patient. SIB schedule prescribes 54 Gy, 60 Gy and 70 Gy in 30 fractions for elective nodes (both sides), involved nodes (right side) and primary nasopharynx respectively, using 1, 2 or 3 arcs RapidArc (RA) or 7 field Sliding Window (SW) techniques. Patient specific quality control measurements were performed using EPID. Varian Portal Dosimetry was used with local gamma analysis using 2%/2 mm and 3%/3 mm criteria with 10% threshold. Results: All plans met the criteria of dose to OARs: D2% of the spinal cord and the brainstem on average were 35 Gy and 35.5 Gy; mean dose of the left parotid on average was 22.9 Gy. Patient specific QC was performed without any interruption. MUs for 1, 2, 3 arcs and 7 field SW were 602, 706, 696 and 2447, respectively. Gamma analysis on EPID images gave 96.2%, 96.2%, 96.7%, 82.6% and 98, 8%, 98.9%, 99.3%, 92, 1% passing rate on average for 2%/ 2 mm and 3%/ 3 mm criteria, respectively. Conclusions: All treatment techniques are suitable for NPC irradiation with SIB in terms of OAR toxicity although RA with 2 or 3 arcs are more preferable in terms of number of MUs. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 148
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.471 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7291.xml