[P137] Joint estimation of radiation-induced late toxicity and cancer recurrence risks for bilateral breast cancer after photon versus spot-scanning proton therapy. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P137] Joint estimation of radiation-induced late toxicity and cancer recurrence risks for bilateral breast cancer after photon versus spot-scanning proton therapy. (August 2018)
- Main Title:
- [P137] Joint estimation of radiation-induced late toxicity and cancer recurrence risks for bilateral breast cancer after photon versus spot-scanning proton therapy
- Authors:
- Stick, Line Bjerregaard
Yu, Jen
Lundgaard, Anni Young
Vogelius, Ivan - Abstract:
- Abstract : Purpose: Joint estimation of risks of radiation-induced secondary lung cancer (SLC) and ischemic heart disease (IHD) modeled with consideration of patient-level risk factors and risk of cancer recurrence caused by compromising target coverage. Methods: Five patients with bilateral breast cancer were treated with postoperative radiotherapy in 2013–2016: two patients received chest wall and comprehensive nodal irradiation (2 Gy x 25), two patients received whole breast irradiation (2.67 Gy x 15) and one patient received whole breast and left-sided lymph node irradiation (2 Gy x 25). Two patients were treated with 3D-CRT, three patients with VMAT. All patients were re-planned with intensity modulated spot-scanning proton therapy. One or three fields were used (anterior, left anterior oblique and right anterior oblique) with multi-field optimization. Models estimating risks of SLC and IHD were developed from published dose-response data and a model for risk of recurrence was derived based on hazard ratios from published randomized trials. Results: The average mean heart dose was 7.6 (range, 1.5–12.7) Gy for the photon plans while mean heart dose was below 0.4 Gy (RBE) for proton plans in all patients using protons (RBE, relative biological effectiveness, assuming RBE = 1.1). The average values of the mean lung dose and V20Gy were 12.2 (range, 5.2–16.3) Gy and 20.7% (range, 10.1%-27.4%) for photon plans, and 5.0 (range, 0.8–9.2) Gy (RBE) and 9.6% (range, 0.8%-19.1%)Abstract : Purpose: Joint estimation of risks of radiation-induced secondary lung cancer (SLC) and ischemic heart disease (IHD) modeled with consideration of patient-level risk factors and risk of cancer recurrence caused by compromising target coverage. Methods: Five patients with bilateral breast cancer were treated with postoperative radiotherapy in 2013–2016: two patients received chest wall and comprehensive nodal irradiation (2 Gy x 25), two patients received whole breast irradiation (2.67 Gy x 15) and one patient received whole breast and left-sided lymph node irradiation (2 Gy x 25). Two patients were treated with 3D-CRT, three patients with VMAT. All patients were re-planned with intensity modulated spot-scanning proton therapy. One or three fields were used (anterior, left anterior oblique and right anterior oblique) with multi-field optimization. Models estimating risks of SLC and IHD were developed from published dose-response data and a model for risk of recurrence was derived based on hazard ratios from published randomized trials. Results: The average mean heart dose was 7.6 (range, 1.5–12.7) Gy for the photon plans while mean heart dose was below 0.4 Gy (RBE) for proton plans in all patients using protons (RBE, relative biological effectiveness, assuming RBE = 1.1). The average values of the mean lung dose and V20Gy were 12.2 (range, 5.2–16.3) Gy and 20.7% (range, 10.1%-27.4%) for photon plans, and 5.0 (range, 0.8–9.2) Gy (RBE) and 9.6% (range, 0.8%-19.1%) for proton plans. Median excess absolute risk (EAR) of SLC by age 80 for non-smokers/smokers was 2.6% (range, 0.6%-2.8%)/5.3% (range, 1.1%-5.7%) with photon therapy and 1.2% (range, 0.1%-1.6%)/2.4% (range, 0.2%-3.2%) with proton therapy. For the photon plans median EAR of IHD by age 80 was 2.8% (range, 0.2%-3.2%)/4.5% (range, 0.5%-5.6%) without/with cardiac risk factors whereas risks were below 0.2% for both scenarios using protons. Median EAR of recurrence or death by ten years was 0.9% (range, 0.1%-1.9%) with photons and 0.1% (range, 0.1%-0.3%) with protons. Conclusions: Proton therapy did reduce the predicted risk of SLC and IHD by up to 3.3% and 5.5%, respectively, and the risk of recurrence by up to 1.6% in individual patients. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 138
- Page End:
- 139
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.445 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7291.xml