[P234] Waiting and treatment time analysis for radiation therapy treatments. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P234] Waiting and treatment time analysis for radiation therapy treatments. (August 2018)
- Main Title:
- [P234] Waiting and treatment time analysis for radiation therapy treatments
- Authors:
- Ambroa Rey, Eva Maria
Giménez, David Navarro
Quiroga, Julia García-Miguel
Pardos, Roberto Gomez
Ramirez, Antoni
Truyols, Montserrat Colomer - Abstract:
- Abstract : Purpose: To analyze the total treatment time and waiting time for the patients in our radiation oncology department. Method: Patient treatment and waiting times were analyzed for a total of 3937 appointments during the last 3 years in three linear accelerators (Agility, Synergy and Infinity). With Elekta's MOSAIQ Radiation Oncology information system (version 2.60, IMPAC Medical Systems), all patient information is collected and accessible, so you can create exhaustive reports. For this study a report including arrival time, wait time, treatment time and total time in the department was created for all radiotherapy treatments. Agility and Synergy are located in the same site, but Infinity is in a satellite location. Agility machine is dedicated mostly to VMAT treatments, meanwhile Synergy carry on only 3D treatments and Infinity performs VMAT as well as 3D treatments. Results: Medium total treatment time was 15.1 min; median was 13.9 min. On average, patients arrive 30.5 min before the scheduled time. Therefore mean total time in the department was 45.6 min. In addition, for each machine, results were as follow: Agility: 1214 appointments. Average (minutes): early arrival 44.7, total time 45.3, wait time 30.6 and treatment time 14.8. Only 9.6% of the appointments arrived late. Synergy: 1541 appointments. Average (minutes): early arrival 36.8, total time 45.5, wait time 29.8 and treatment time 15.7. A 9.4% of the appointments arrived late. Infinity: 1182Abstract : Purpose: To analyze the total treatment time and waiting time for the patients in our radiation oncology department. Method: Patient treatment and waiting times were analyzed for a total of 3937 appointments during the last 3 years in three linear accelerators (Agility, Synergy and Infinity). With Elekta's MOSAIQ Radiation Oncology information system (version 2.60, IMPAC Medical Systems), all patient information is collected and accessible, so you can create exhaustive reports. For this study a report including arrival time, wait time, treatment time and total time in the department was created for all radiotherapy treatments. Agility and Synergy are located in the same site, but Infinity is in a satellite location. Agility machine is dedicated mostly to VMAT treatments, meanwhile Synergy carry on only 3D treatments and Infinity performs VMAT as well as 3D treatments. Results: Medium total treatment time was 15.1 min; median was 13.9 min. On average, patients arrive 30.5 min before the scheduled time. Therefore mean total time in the department was 45.6 min. In addition, for each machine, results were as follow: Agility: 1214 appointments. Average (minutes): early arrival 44.7, total time 45.3, wait time 30.6 and treatment time 14.8. Only 9.6% of the appointments arrived late. Synergy: 1541 appointments. Average (minutes): early arrival 36.8, total time 45.5, wait time 29.8 and treatment time 15.7. A 9.4% of the appointments arrived late. Infinity: 1182 appointments. Average (minutes): early arrival 22.0, total time 46.1, wait time 31.3 and treatment time 14.8. A 21.9% of the appointments arrived late. Conclusions: In summary, patient waiting time and total time are very similar for the three machines. Despite the fact all VMAT treatments have a daily cone beam CT for patient positioning; medium treatment time for Agility is similar to the other machines which perform less VMAT treatments. Furthermore, many patients depend on public/private transport to arrive to their appointments; Infinity machine has the higher rate of late appointments, which could be related with a problem in the transport system. Therefore these results not only provide feedback but also could allow detecting problems and consequently improving waiting times for the patients. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 167
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.520 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7291.xml