[P061] Calculation of beam quality parameters for X-ray mammography spectra: A monte carlo simulation study. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P061] Calculation of beam quality parameters for X-ray mammography spectra: A monte carlo simulation study. (August 2018)
- Main Title:
- [P061] Calculation of beam quality parameters for X-ray mammography spectra: A monte carlo simulation study
- Authors:
- Atak, Haluk
- Abstract:
- Abstract : Purpose: Breast cancer is known to be the most malignant type of cancer among women in the world. By X-ray mammographic imaging, the disease can be detected and then an early stage treatment can be started following this. For a reliable imaging, beam quality parameters should be precisely determined. However, measurement of X-ray beam quality parameters necessitates using specific equipment. An efficient way for determining these parameters is to utilize scientifically proven and verified Monte Carlo simulation codes. Methods: Monte Carlo simulations are widely used in digital mammography imaging research. In this work, MCNP5 was used for simulating generation of X-ray spectrum including both bremsstrahlung and characteristic X-rays. Electron beam and target (anode) were modelled as specified in the Report of AAPM Task Group 195: Monte Carlo Reference Data Sets for Imaging Research. Results: X-ray quality parameters such as Aluminum (Al) equivalent half-value layer (HVL), Al equivalent effective energy, average energy, and air kerma of the simulated polyenergetic X-ray beams were calculated and tabulated for a wide range of commercially available mammographic X-ray tube voltage (kVp) and target/filter material and thickness combinations (molybdenum/molybdenum, molybdenum/rhodium, rhodium/rhodium, tungsten/rhodium, tungsten/silver, and tungsten/aluminum). All calculated parameters were then fitted to second-degree polynomial surface equations as a function of kVpAbstract : Purpose: Breast cancer is known to be the most malignant type of cancer among women in the world. By X-ray mammographic imaging, the disease can be detected and then an early stage treatment can be started following this. For a reliable imaging, beam quality parameters should be precisely determined. However, measurement of X-ray beam quality parameters necessitates using specific equipment. An efficient way for determining these parameters is to utilize scientifically proven and verified Monte Carlo simulation codes. Methods: Monte Carlo simulations are widely used in digital mammography imaging research. In this work, MCNP5 was used for simulating generation of X-ray spectrum including both bremsstrahlung and characteristic X-rays. Electron beam and target (anode) were modelled as specified in the Report of AAPM Task Group 195: Monte Carlo Reference Data Sets for Imaging Research. Results: X-ray quality parameters such as Aluminum (Al) equivalent half-value layer (HVL), Al equivalent effective energy, average energy, and air kerma of the simulated polyenergetic X-ray beams were calculated and tabulated for a wide range of commercially available mammographic X-ray tube voltage (kVp) and target/filter material and thickness combinations (molybdenum/molybdenum, molybdenum/rhodium, rhodium/rhodium, tungsten/rhodium, tungsten/silver, and tungsten/aluminum). All calculated parameters were then fitted to second-degree polynomial surface equations as a function of kVp and filter thickness for each target/filter combination. Conclusions: This work is essential and flexible in the sense that it provides a reliable and quick look-up database for those performing mammographic patient dose and image quality calculations. In addition, it could be taken as a starting point for generation of quality data for entire diagnostic X-ray energy range, e.g. 20–140 kVp, for any combination of target/filter. On the other hand, with this study, it can be deduced that important mammographic parameters can be precisely calculated with Monte Carlo methods, which would otherwise need for expensive and complicated experimental equipment and much more time. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 117
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.384 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7290.xml