[P033] Evaluation, comparison and optimization of the effects of manual versus software automated protocols on radiation dose and image quality in paediatric chest computed tomography. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P033] Evaluation, comparison and optimization of the effects of manual versus software automated protocols on radiation dose and image quality in paediatric chest computed tomography. (August 2018)
- Main Title:
- [P033] Evaluation, comparison and optimization of the effects of manual versus software automated protocols on radiation dose and image quality in paediatric chest computed tomography
- Authors:
- Bellesi, Luca
Argentieri, Gianluca
Del Grande, Filippo
Presilla, Stefano
Soldati, Corrado
Gaudino, Diego
Pupillo, Francesco
Piliero, Maria Antonietta
Casiraghi, Margherita
Puligheddu, Carla - Abstract:
- Abstract : Purpose: The aim of this study was to compare software automated versus radiologist manual CT protocols optimization strategies by using a CT phantom with different acquisition parameters and iterative reconstruction (IR) levels in order to maintain high image quality while decreasing dose and image noise. Methods: A CATPHAN CT phantom underwent simulated pediatric chest CT scans using both automated and manual parameters optimization approaches performed by a radiologist. Phantom was scanned within different protocols varying kV, mAs, pitch, IR. The subjective and objective image qualities were assessed by both radiologists and software. Computed tomography dose index (CTDI) and dose-length product (DLP) values were collected and analysed. Equivalent dose to organ at risk (OAR) was assessed with a Monte Carlo system using a digital phantom simulating a six year old pediatric patient. Results: Dose to OAR, CTDIvol and DLP were substantially lower (90%, 58% and 32% respectively) adopting a manual approach, maintaining a good subjective image quality as demonstrated by a human visual scoring test evaluation on images. Through CT acquisitions, linearity and resolution were constant while image noise (mean −6.4, standard deviation 10.1) and uniformity (mean −6.4, standard deviation 10.1, ) varied between scans, as observed by 3 experienced radiologists by visual score analysis. Iterative reconstruction was associated with a further dose reduction using level 3 (max 6)Abstract : Purpose: The aim of this study was to compare software automated versus radiologist manual CT protocols optimization strategies by using a CT phantom with different acquisition parameters and iterative reconstruction (IR) levels in order to maintain high image quality while decreasing dose and image noise. Methods: A CATPHAN CT phantom underwent simulated pediatric chest CT scans using both automated and manual parameters optimization approaches performed by a radiologist. Phantom was scanned within different protocols varying kV, mAs, pitch, IR. The subjective and objective image qualities were assessed by both radiologists and software. Computed tomography dose index (CTDI) and dose-length product (DLP) values were collected and analysed. Equivalent dose to organ at risk (OAR) was assessed with a Monte Carlo system using a digital phantom simulating a six year old pediatric patient. Results: Dose to OAR, CTDIvol and DLP were substantially lower (90%, 58% and 32% respectively) adopting a manual approach, maintaining a good subjective image quality as demonstrated by a human visual scoring test evaluation on images. Through CT acquisitions, linearity and resolution were constant while image noise (mean −6.4, standard deviation 10.1) and uniformity (mean −6.4, standard deviation 10.1, ) varied between scans, as observed by 3 experienced radiologists by visual score analysis. Iterative reconstruction was associated with a further dose reduction using level 3 (max 6) in order to avoid texture effect. Conclusions: In a simulated pediatric chest CT study, radiologist guided acquisition resulted the best choice in terms of optimal dose-image quality ratio while maintaining good image quality. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 107
- Page End:
- 108
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.358 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7290.xml