[OA039] Contouring and dose reporting for lower urinary tract sub-structures in cervix cancer. (August 2018)
- Record Type:
- Journal Article
- Title:
- [OA039] Contouring and dose reporting for lower urinary tract sub-structures in cervix cancer. (August 2018)
- Main Title:
- [OA039] Contouring and dose reporting for lower urinary tract sub-structures in cervix cancer
- Authors:
- Spampinato, Sofia
Fokdal, Lars
Marinovskij, Edvard
Axelsen, Susanne
Pedersen, Erik Morre
Pötter, Richard
Lindegaard, Jacob
Tanderup, Kari - Abstract:
- Abstract : Purpose: Radiotherapy related bladder morbidity include various clinical endpoints (i.e. frequency, cystitis, incontinence, bleeding, fistula) that may be related to various anatomical sub-structures. Evaluation and reporting of bladder dose is currently based on the total bladder volume with contouring of the outer wall. This study aims to investigate contouring and dose evaluation of several bladder sub-structures potentially responsible for urinary morbidity after radiochemotherapy and Image Guided Adaptive Brachytherapy (IGABT) in locally advanced cervical cancer (LACC). Methods: The study hypothesis is that different bladder structures are related to different morbidity endpoints. Therefore, a methodology for contouring subvolumes (trigone, bladder neck, urethra) was established. Structures were contoured for all BT fraction extracting DVH parameters: outer bladder wall ( D 2 cm 3, D 0.1 cm 3 ), ICRU Bladder point, trigone ( D 2 cm 3, D 0.1 cm 3 ), bladder neck ( D 0.1 cm 3 ), and urethra (volume, D 0.1 cm 3, D 2 cm 3 . A total of 40 LACC [FIGO Stage: IB(3), IIB(30), IIIA(1), IIIB(1), IVB(5)] patients according to the EMBRACE protocol was selected. Results: The reported values represent the cumulative EBRT+BT dose in EQD2. Median D 2 cm 3 values were 71.7 [59.2–81.8] and 56.2 [47.8–69.3] Gy for bladder wall and trigone, respectively. Bladder wall dose was systematically higher, and hotspots often placed outside the trigone. Median ICRU point dose was 63.0Abstract : Purpose: Radiotherapy related bladder morbidity include various clinical endpoints (i.e. frequency, cystitis, incontinence, bleeding, fistula) that may be related to various anatomical sub-structures. Evaluation and reporting of bladder dose is currently based on the total bladder volume with contouring of the outer wall. This study aims to investigate contouring and dose evaluation of several bladder sub-structures potentially responsible for urinary morbidity after radiochemotherapy and Image Guided Adaptive Brachytherapy (IGABT) in locally advanced cervical cancer (LACC). Methods: The study hypothesis is that different bladder structures are related to different morbidity endpoints. Therefore, a methodology for contouring subvolumes (trigone, bladder neck, urethra) was established. Structures were contoured for all BT fraction extracting DVH parameters: outer bladder wall ( D 2 cm 3, D 0.1 cm 3 ), ICRU Bladder point, trigone ( D 2 cm 3, D 0.1 cm 3 ), bladder neck ( D 0.1 cm 3 ), and urethra (volume, D 0.1 cm 3, D 2 cm 3 . A total of 40 LACC [FIGO Stage: IB(3), IIB(30), IIIA(1), IIIB(1), IVB(5)] patients according to the EMBRACE protocol was selected. Results: The reported values represent the cumulative EBRT+BT dose in EQD2. Median D 2 cm 3 values were 71.7 [59.2–81.8] and 56.2 [47.8–69.3] Gy for bladder wall and trigone, respectively. Bladder wall dose was systematically higher, and hotspots often placed outside the trigone. Median ICRU point dose was 63.0 [49.8–80.5] Gy, Median D 0.1 cm 3 values for bladder wall, trigone, bladder neck and urethra were 85.6 [68.2–109.8], 70.9 [48.3–105.6], 61.7 [46.5–76.9], and 50.6 [45.6–64.7] Gy, respectively. Median urethra volume and D 2 cm 3 dose were 3.2 [1.4–6.5] cm 3 and 47.9 [44.8–58.7] Gy, respectively. Conclusion: The study showed that the parameters currently used for IGABT bladder dose reporting ( D 2 cm 3, ICRU point) do not fully and accurately describe the dose distribution in the lower urinary tract sub-structures. D2cm3 for the outer bladder wall is often higher than trigone dose and in many cases the ICRU bladder point is not a good indicator. It is interesting to note that urethra volume may be relevant for endpoints such as incontinence varied across patients. Further understanding of dose-effect relationships for the bladder may be gained by future systematic delineation of bladder sub-structures. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 15
- Page End:
- 16
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.111 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7290.xml