[OA165] Optimization of quantitative 99MTC-MAA SPECT/CT imaging for 90Y RADIOEMBOLIZATION: A 3D-printed phantom study. (August 2018)
- Record Type:
- Journal Article
- Title:
- [OA165] Optimization of quantitative 99MTC-MAA SPECT/CT imaging for 90Y RADIOEMBOLIZATION: A 3D-printed phantom study. (August 2018)
- Main Title:
- [OA165] Optimization of quantitative 99MTC-MAA SPECT/CT imaging for 90Y RADIOEMBOLIZATION: A 3D-printed phantom study
- Authors:
- Ungania, Sara
Nocentini, Sandro
Iaccarino, Giuseppe
D'Andrea, Marco
D'Arienzo, Marco
Cacciatore, Alessandra
Sciuto, Rosa
Vallati, Giulio
Pizzi, Giuseppe
Strigari, Lidia
Guerrisi, Maria G. - Abstract:
- Abstract : Purpose: Radioembolization (RE) with 90 Y-microspheres has gained widespread acceptance as a safe and effective technique for treating liver malignancies. Accurate quantification in RE is a key step in treatment planning optimization and it is becoming a pressing issue in the light of the Directive 2013/59/EURATOM, stating that individual dose planning must be enforced in legislation by EU member states by February 2018. The aim of this study was to develop a SPECT/CT imaging protocol for quantitative imaging optimization in RE based on a novel anthropomorphic 3D-printed phantom. Methods and materials: A SPECT/CT system provided with a novel software for imaging quantification was used to assess the quantitative accuracy of 99m Tc-MAA SPECT imaging for treatment planning in RE. Gamma camera calibration factors and recovery coefficients were determined performing preliminary SPECT/CT acquisitions of a homogeneous and a NEMA/IEC phantom, respectively. The quantification procedure was then validated using a 3D-printed anthropomorphic phantom provided with a fillable liver section and multiple inserts. Raw data reconstruction was performed using two independent software: i) the built-in xSPECT package, using both the Ordered Subset Expectation–Maximization (OSEM) and the Ordered Subset Conjugated Gradient (OSCG) algorithm; ii) the commercially available QSPECT software based on OSEM method. All reconstructed images were manually fused and appropriate regions ofAbstract : Purpose: Radioembolization (RE) with 90 Y-microspheres has gained widespread acceptance as a safe and effective technique for treating liver malignancies. Accurate quantification in RE is a key step in treatment planning optimization and it is becoming a pressing issue in the light of the Directive 2013/59/EURATOM, stating that individual dose planning must be enforced in legislation by EU member states by February 2018. The aim of this study was to develop a SPECT/CT imaging protocol for quantitative imaging optimization in RE based on a novel anthropomorphic 3D-printed phantom. Methods and materials: A SPECT/CT system provided with a novel software for imaging quantification was used to assess the quantitative accuracy of 99m Tc-MAA SPECT imaging for treatment planning in RE. Gamma camera calibration factors and recovery coefficients were determined performing preliminary SPECT/CT acquisitions of a homogeneous and a NEMA/IEC phantom, respectively. The quantification procedure was then validated using a 3D-printed anthropomorphic phantom provided with a fillable liver section and multiple inserts. Raw data reconstruction was performed using two independent software: i) the built-in xSPECT package, using both the Ordered Subset Expectation–Maximization (OSEM) and the Ordered Subset Conjugated Gradient (OSCG) algorithm; ii) the commercially available QSPECT software based on OSEM method. All reconstructed images were manually fused and appropriate regions of interest (ROIs) were drawn on the MIM 6.1.7 system. Results: The measured activity concentration is consistent within 3% with the expected activity concentration values. This is in keeping with the overall accuracy ( < 10%) stated by the manufacturer. No substantial differences were reported between xSPECT with OSCG or OSEM in terms of relative activity. However, a 20% difference was found between ROIs extracted from images reconstructed with xSPECT and QSPECT using OSEM. Several artifacts were visible in the QSPECT reconstruction, likely due to the limited area used for attenuation and scatter corrections within the software. Conclusions: The investigated protocol based on the innovative xSPECT tool allows an accurate absolute quantification within 3%. QSPECT software provides the poorest results with several artifacts as well as intrinsic dishomogeneities. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 63
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.237 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7288.xml