[P145] Evaluation of the angular accuracy influence over Octavius4D results for vmatpre-treatment QA. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P145] Evaluation of the angular accuracy influence over Octavius4D results for vmatpre-treatment QA. (August 2018)
- Main Title:
- [P145] Evaluation of the angular accuracy influence over Octavius4D results for vmatpre-treatment QA
- Authors:
- Ramirez, Antoni
Garcia-Miguel, Julia
Parcerisa, Marc
Pujol, Ramon
Navarro, David
Gomez, Roberto
Ambroa, Eva
Lopez, Ana
Amat, Debora
Frontera, Gemma
Colomer, Montserrat - Abstract:
- Abstract : Purpose: Following the detection of an anomaly on Octavius4D pre-treatment QA results for some patients, an investigation to determine its origin was conducted. A problem was found on the angular measurements performed by the inclinometer. The aim of this work is to study the influence of the angular accuracy on Octavius4D results and the ability of the Octavius4D system to detect angular deviations. Methods: Measurements were performed using Octavius4D modular system and analysed using Verisoft 7.0 (PTW-Freiburg, Freiburg, Germany). Measurements performed using the malfunctioning inclinometer for 61 patients undergoing VMAT treatments were compared with the same measurements carried out using a new inclinometer. Two different locations were analysed: 40 prostates and 21 pelvises (15 of them were prostates with SIB and 6 of them were gynaecologic pathologies). 3D gamma analysis was computed over the entire volume with acceptance criteria of 3% dose difference and 3 mm distance to agreement. 2%-2 mm gamma test was also calculated. Dose differences were calculated referenced to the maximum dose in calculated volume and the threshold considered was 10% of the maximum dose. The angular lectures of the inclinometer were obtained from .xcc raw files. Results: Mean angle differences at 180 degrees (where the greatest difference was observed) are 2.25° for prostates and 2.21° for pelvises. In several cases, the 3%-3 mm gamma criterion does not show any difference betweenAbstract : Purpose: Following the detection of an anomaly on Octavius4D pre-treatment QA results for some patients, an investigation to determine its origin was conducted. A problem was found on the angular measurements performed by the inclinometer. The aim of this work is to study the influence of the angular accuracy on Octavius4D results and the ability of the Octavius4D system to detect angular deviations. Methods: Measurements were performed using Octavius4D modular system and analysed using Verisoft 7.0 (PTW-Freiburg, Freiburg, Germany). Measurements performed using the malfunctioning inclinometer for 61 patients undergoing VMAT treatments were compared with the same measurements carried out using a new inclinometer. Two different locations were analysed: 40 prostates and 21 pelvises (15 of them were prostates with SIB and 6 of them were gynaecologic pathologies). 3D gamma analysis was computed over the entire volume with acceptance criteria of 3% dose difference and 3 mm distance to agreement. 2%-2 mm gamma test was also calculated. Dose differences were calculated referenced to the maximum dose in calculated volume and the threshold considered was 10% of the maximum dose. The angular lectures of the inclinometer were obtained from .xcc raw files. Results: Mean angle differences at 180 degrees (where the greatest difference was observed) are 2.25° for prostates and 2.21° for pelvises. In several cases, the 3%-3 mm gamma criterion does not show any difference between measurements carried out using both inclinometers. The 2%-2 mm gamma criterion leads to a mean difference of 1.71% for prostates and 4.04% for pelvises. In all cases 3%-3 mm gamma passing rates were greater than 95%, making difficult to identify this problem by only applying this criterion. It is observable a dependence of the results on the symmetry of the dose distribution. PTVs comprising only the prostate which are highly symmetrical had lesser variations than more complex treatments. Conclusions: 2% dose difference and 2 mm distance to agreement criterion showed better ability to find angular differences when performing gamma analysis for VMAT treatments. This can be potentially used to discover problems in gantry position but a further analysis must be performed. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 141
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.451 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7288.xml