[P286] Study on semi-automatically evaluated micronucleus frequency changes in patients with prostate adenocarcinoma undergoing low and high dose rate brachytherapy. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P286] Study on semi-automatically evaluated micronucleus frequency changes in patients with prostate adenocarcinoma undergoing low and high dose rate brachytherapy. (August 2018)
- Main Title:
- [P286] Study on semi-automatically evaluated micronucleus frequency changes in patients with prostate adenocarcinoma undergoing low and high dose rate brachytherapy
- Authors:
- Hulber, Timea
Kis, Enikő
Zsuzsa Kocsis, S.
Sáfrány, Géza
Pesznyák, Csilla - Abstract:
- Abstract : Purpose: We compared the biological damaging effect of low and high dose rate brachytherapy (LDR and HDR) in healthy tissues of patients with prostate adenocarcinoma by following up the changes of DNA damage with cytokinesis-blocked micronucleus assay (CBMN) during and after the treatment. Methods: The CBMN assay was proven by literature to be good indicator of received dose during partial-body radiotherapy. The first blood samples were collected preceding the radiation therapy and the next ones in regular intervals after the seed insertion (LDR) or the end of treatment (HDR) (once every 3 month during the first year). The automatic analysis (scanning and image processing) was conducted by a dedicated totally automatized microscopic system. Results: We determined the MN frequency of 5 patients from each treatment group automatically and manually as well. We found that in order to ensure the reliability of the comparison of automatic scoring results an extra step has to be introduced for sample quality improvement. This way the tendency of MN frequency versus elapsed time became possible to be accurately identified and analysed for both brachytherapy techniques. Due to the relatively low whole-body equivalent dose, the best results were achieved with the user-supervised semi-automatic combined method which merges the advantages of the accuracy of manual revision and the rapidity of the automation. Conclusions: Although the signal is comparable with the order ofAbstract : Purpose: We compared the biological damaging effect of low and high dose rate brachytherapy (LDR and HDR) in healthy tissues of patients with prostate adenocarcinoma by following up the changes of DNA damage with cytokinesis-blocked micronucleus assay (CBMN) during and after the treatment. Methods: The CBMN assay was proven by literature to be good indicator of received dose during partial-body radiotherapy. The first blood samples were collected preceding the radiation therapy and the next ones in regular intervals after the seed insertion (LDR) or the end of treatment (HDR) (once every 3 month during the first year). The automatic analysis (scanning and image processing) was conducted by a dedicated totally automatized microscopic system. Results: We determined the MN frequency of 5 patients from each treatment group automatically and manually as well. We found that in order to ensure the reliability of the comparison of automatic scoring results an extra step has to be introduced for sample quality improvement. This way the tendency of MN frequency versus elapsed time became possible to be accurately identified and analysed for both brachytherapy techniques. Due to the relatively low whole-body equivalent dose, the best results were achieved with the user-supervised semi-automatic combined method which merges the advantages of the accuracy of manual revision and the rapidity of the automation. Conclusions: Although the signal is comparable with the order of changes, the automation-aided evaluation decreased the achieved uncertainty and made it possible to identify a definite and significant tendency in the change of MN frequency for LDR and HDR as well. Acknowledgment: This work has been carried out in the frame of VKSZ 14-1-2015-0021 Hungarian project supported by the National Research, Development and Innovation Fund. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 182
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.561 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7288.xml