[OA026] Design of an optimised bow-tie filter for cone-beam CT image guidance for children. (August 2018)
- Record Type:
- Journal Article
- Title:
- [OA026] Design of an optimised bow-tie filter for cone-beam CT image guidance for children. (August 2018)
- Main Title:
- [OA026] Design of an optimised bow-tie filter for cone-beam CT image guidance for children
- Authors:
- Bryce-Atkinson, Abigail
Whitfield, Gillian
Herk, Marcel - Abstract:
- Abstract : Purpose: Children can receive excessive imaging dose from cone-beam CT (CBCT) during image-guided radiotherapy due to use of protocols designed for adults. Lower dose CBCT is a high priority for reducing the risk of radiation induced late effects in children. The range of imaging doses can be reduced by lowering exposure using an optimal 'child-sized' bow-tie filter with additional attenuation and tailored shape. We present a filter design using measurements from paediatric CBCT data and simulate its impact on image quality and registration accuracy. Methods: The filter was designed to produce uniform signal across the average paediatric patient and provide additional attenuation compared to a standard (adult) bow-tie filter. To estimate the average patient thickness across the detector plane, we used the signal intensity profiles of projection images acquired from 15 paediatric patients (ages 3–17 years) with various tumour sites. The intensity values were converted to an estimate of patient thickness using the Beer-Lambert law, with all tissues approximated as water. We produced a symmetrical design accounting for attenuation through the average patient across the detector. CBCT scans including the added noise resulting from attenuation of the new filter were simulated by modifying projection images before reconstruction. Simulated scan quality was assessed visually and by testing registration accuracy, comparing the table correction to that for the originalAbstract : Purpose: Children can receive excessive imaging dose from cone-beam CT (CBCT) during image-guided radiotherapy due to use of protocols designed for adults. Lower dose CBCT is a high priority for reducing the risk of radiation induced late effects in children. The range of imaging doses can be reduced by lowering exposure using an optimal 'child-sized' bow-tie filter with additional attenuation and tailored shape. We present a filter design using measurements from paediatric CBCT data and simulate its impact on image quality and registration accuracy. Methods: The filter was designed to produce uniform signal across the average paediatric patient and provide additional attenuation compared to a standard (adult) bow-tie filter. To estimate the average patient thickness across the detector plane, we used the signal intensity profiles of projection images acquired from 15 paediatric patients (ages 3–17 years) with various tumour sites. The intensity values were converted to an estimate of patient thickness using the Beer-Lambert law, with all tissues approximated as water. We produced a symmetrical design accounting for attenuation through the average patient across the detector. CBCT scans including the added noise resulting from attenuation of the new filter were simulated by modifying projection images before reconstruction. Simulated scan quality was assessed visually and by testing registration accuracy, comparing the table correction to that for the original higher dose images. Results: The resulting filter had a central thickness of 15.53 mm of Aluminium, corresponding to a fivefold reduction in signal compared to the use of the standard filter (approximately decreasing dose from 1.5 mGy to 0.33 mGy per scan). The thickness increased to 29.87 mm at the outer edge, following a curvature described by a polynomial function relating filter thickness to patient thickness across the detector. Simulated scans showed increased noise but clear bone/soft tissue boundaries. Registration remained accurate; most scans had table correction vector discrepancies within 1 mm (max 1.09 mm). Conclusions: We have designed an optimised bow-tie filter for children. This dedicated filter design should allow considerable dose reduction to the patient, maintaining sufficient image quality and accurate registration. Observer studies on the acceptability of very low dose images in clinical practice are underway. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 11
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.098 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7287.xml