[P168] Volumetric modulated arc therapy using multi-criteria dose plan optimization for anal cancer – Feasibility of selective sparing of organs at risk. (August 2018)
- Record Type:
- Journal Article
- Title:
- [P168] Volumetric modulated arc therapy using multi-criteria dose plan optimization for anal cancer – Feasibility of selective sparing of organs at risk. (August 2018)
- Main Title:
- [P168] Volumetric modulated arc therapy using multi-criteria dose plan optimization for anal cancer – Feasibility of selective sparing of organs at risk
- Authors:
- Rønde, Heidi S.
Wee, Leonard
Bokrantz, Rasmus
Pløen, John
Appelt, Ane L. - Abstract:
- Abstract : Purpose: Radiotherapy treatment plan optimization often requires trade-offs between different organs at risk (OARs). This may facilitate individualized plan optimization, where sparing of specific OARs can be incorporated into plan selection. We previously demonstrated this for IMRT using multi-criteria dose plan optimization (MCO). We here present initial results for volumetric modulated arc therapy (VMAT) MCO. Methods: VMAT dose plans were generated for ten representative anal cancer patients. Prescribed dose was 53.75 Gy to tumour (simultaneous integrated boost) and 45 Gy to elective nodes in 25 fractions. Plan optimization was done in RayStation® (v5.99.0.16 research build). Dual arc non-MCO VMAT plans were optimized with physician-defined organ-sparing priorities. Three additional VMAT dose distributions were optimized using MCO, representing a span of clinically relevant objectives: 1) minimum acceptable target coverage with physician-defined organ-sparing priorities; 2) maximum bowel sparing without losing target coverage (if needed at expense of the bladder); 3) maximum bladder sparing without losing target coverage (if needed at expense of the bowel). VMAT-MCO dosimetry metrics were compared to non-MCO VMAT plans; and feasibility of selective OAR sparing (bladder or bowel) with VMAT-MCO was compared to previously published findings. Results: All plans satisfied constraints for target coverage. Non-MCO and VMAT-MCO plans showed similar conformity indicesAbstract : Purpose: Radiotherapy treatment plan optimization often requires trade-offs between different organs at risk (OARs). This may facilitate individualized plan optimization, where sparing of specific OARs can be incorporated into plan selection. We previously demonstrated this for IMRT using multi-criteria dose plan optimization (MCO). We here present initial results for volumetric modulated arc therapy (VMAT) MCO. Methods: VMAT dose plans were generated for ten representative anal cancer patients. Prescribed dose was 53.75 Gy to tumour (simultaneous integrated boost) and 45 Gy to elective nodes in 25 fractions. Plan optimization was done in RayStation® (v5.99.0.16 research build). Dual arc non-MCO VMAT plans were optimized with physician-defined organ-sparing priorities. Three additional VMAT dose distributions were optimized using MCO, representing a span of clinically relevant objectives: 1) minimum acceptable target coverage with physician-defined organ-sparing priorities; 2) maximum bowel sparing without losing target coverage (if needed at expense of the bladder); 3) maximum bladder sparing without losing target coverage (if needed at expense of the bowel). VMAT-MCO dosimetry metrics were compared to non-MCO VMAT plans; and feasibility of selective OAR sparing (bladder or bowel) with VMAT-MCO was compared to previously published findings. Results: All plans satisfied constraints for target coverage. Non-MCO and VMAT-MCO plans showed similar conformity indices (CI) and dose volumes to bladder, although with considerable variation between patients. MCO plans had smaller hotspots in elective volumes (ΔV107% : 3.0%-points, interquartile range (IQR) [1.7–3.9]), but higher dose volumes to bowel (median bowel ΔV45 Gy : 57.5 cm[c]; IQR [21.3–298.0]). Compared to IMRT-MCO, VMAT-MCO demonstrated smaller hotspots and similar CI. VMAT-MCO allowed for redistribution of dose between bladder and bowel, but the optimization space was considerably smaller than for IMRT. To illustrate, median bowel ΔV45 Gy : 19.4 cm 3 ; IQR [2.2–31.1] for bowel sparing VMAT-MCO compared to standard VMAT-MCO; while for IMRT-MCO ΔV45 Gy : 47.6 cm 3 ; IQR [18.6–66.4]. Time spent on optimization was longer for VMAT-MCO due to considerable increase in the calculation and conversion time compared to IMRT-MCO. Conclusions: Selective sparing of OARs in VMAT-MCO facilitates the same trade-offs as IMRT-MCO, but with significantly less room for dose redistribution. While VMAT-MCO plans are clinically acceptable, further improvement of the research implementation is warranted. … (more)
- Is Part Of:
- Physica medica. Volume 52(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 52(2018)Supplement 1
- Issue Display:
- Volume 52, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2018
- Issue Sort Value:
- 2018-0052-2018-0000
- Page Start:
- 147
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.06.468 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7287.xml