Evaluation of ImpediMed SFB7 BIS device for low-impedance measurements. (December 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of ImpediMed SFB7 BIS device for low-impedance measurements. (December 2018)
- Main Title:
- Evaluation of ImpediMed SFB7 BIS device for low-impedance measurements
- Authors:
- Freeborn, Todd J.
Milligan, Ashley
Esco, Michael R. - Abstract:
- Highlights: SFB7 device is 1% accurate down to 10 Ω for frequencies to 100 kHz. SFB7 device is 5% accurate down to 10 Ω for frequencies to 1 MHz. Variability insensitive to temperature in the range from 10 °C to 35 °C. High frequency SFB7 measurements have significant inductive component. Abstract: The SFB7 bioimpedance spectroscopy (BIS) device from ImpediMed is a widely utilized tool for clinical research in a variety of applications, marketed for the estimation of body composition in individuals. This device has a rated accuracy of 1 % for measurements from 50 Ω to 1 k Ω from 3 kHz to 1 MHz, making it an ideal choice for the measurement of full-body impedance. Recent research has also used this device to collect impedance measurements from localized regions of tissue which in some cases may be below the 50 Ω rated value. In this work, the measurements of impedances below 50 Ω are compared to measurements collected from a Keysight E4990A impedance analyzer in this low impedance range. Concluding that the SFB7 device is 1 % accurate for resistance measurements as low as 10 Ω for frequencies below 100 kHz and 5 % accurate for frequencies to 1 MHz. While 1 Ω measurements are possible, their much higher variability decrease their expected accuracy to approximately 5 % for frequencies below 100 kHz and 30 % for frequencies up to 1 MHz.
- Is Part Of:
- Measurement. Volume 129(2018)
- Journal:
- Measurement
- Issue:
- Volume 129(2018)
- Issue Display:
- Volume 129, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 129
- Issue:
- 2018
- Issue Sort Value:
- 2018-0129-2018-0000
- Page Start:
- 20
- Page End:
- 30
- Publication Date:
- 2018-12
- Subjects:
- Bioimpedance -- SFB7 -- Accuracy -- Low-impedance
Weights and measures -- Periodicals
Measurement -- Periodicals
Measurement
Weights and measures
Periodicals
530.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02632241 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.measurement.2018.07.010 ↗
- Languages:
- English
- ISSNs:
- 0263-2241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5413.544700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7266.xml