High-concentration iodinated contrast media for T1-weighted direct magnetic resonance arthrography. Issue 10 (October 2018)
- Record Type:
- Journal Article
- Title:
- High-concentration iodinated contrast media for T1-weighted direct magnetic resonance arthrography. Issue 10 (October 2018)
- Main Title:
- High-concentration iodinated contrast media for T1-weighted direct magnetic resonance arthrography
- Authors:
- Huang, Y.-F.
Hsieh, T.-J.
Chen, Y.-J.
Chen, H.-S.
Kuo, Y.-T.
Yang, Y.-H. - Abstract:
- Abstract : Aim: To quantify in vitro the T1-weighted (T1W) expression of iodinated contrast media (CM), and to compare the in vivo performances of iodinated CM and gadolinium-based CM for T1W direct magnetic resonance imaging (MRI) arthrography. Materials and methods: An in vitro study on a 1.5 T MRI system was performed using Gd-DOTA, a mixture of iopromide and Gd-DOTA, and iopromide alone. The fat-suppressed (FS) T1W signal intensities were measured and analysed. In an in vivo study, 15 normal rabbits were used to compare the expression of iopromide (370 mg iodine/ml), and the mixture of iopromide and diluted Gd-DOTA. In nine of the 15 rabbits, extra-articular administrations of CM were performed to mimic the situation of CM leak. The rabbits were scanned on a 1.5 T MRI system, and the FS T1W sequence and an axial iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) T1W sequence were acquired. Signal intensities were measured and signal-to-noise ratios (SNR) were analysed. Results: In the in vitro study, a higher SNR was noted in a higher concentration of iopromide, and the highest SNR of iopromide was 45.9% of that of Gd-DOTA. In the in vivo study, the iopromide and the mixture were well identified in all rabbits. The SNRs of the intra-articular and extra-articular iopromide and the mixture were significantly higher than the SNR of the muscles in the FS T1W images (all, p< 0.01) and the IDEAL images (all, p< 0.01). Conclusions:Abstract : Aim: To quantify in vitro the T1-weighted (T1W) expression of iodinated contrast media (CM), and to compare the in vivo performances of iodinated CM and gadolinium-based CM for T1W direct magnetic resonance imaging (MRI) arthrography. Materials and methods: An in vitro study on a 1.5 T MRI system was performed using Gd-DOTA, a mixture of iopromide and Gd-DOTA, and iopromide alone. The fat-suppressed (FS) T1W signal intensities were measured and analysed. In an in vivo study, 15 normal rabbits were used to compare the expression of iopromide (370 mg iodine/ml), and the mixture of iopromide and diluted Gd-DOTA. In nine of the 15 rabbits, extra-articular administrations of CM were performed to mimic the situation of CM leak. The rabbits were scanned on a 1.5 T MRI system, and the FS T1W sequence and an axial iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) T1W sequence were acquired. Signal intensities were measured and signal-to-noise ratios (SNR) were analysed. Results: In the in vitro study, a higher SNR was noted in a higher concentration of iopromide, and the highest SNR of iopromide was 45.9% of that of Gd-DOTA. In the in vivo study, the iopromide and the mixture were well identified in all rabbits. The SNRs of the intra-articular and extra-articular iopromide and the mixture were significantly higher than the SNR of the muscles in the FS T1W images (all, p< 0.01) and the IDEAL images (all, p< 0.01). Conclusions: A high-concentration iodinated CM can provide good imaging quality for T1W direct MRI arthrography, and may be an alternative option in certain clinical situations. … (more)
- Is Part Of:
- Clinical radiology. Volume 73:Issue 10(2018)
- Journal:
- Clinical radiology
- Issue:
- Volume 73:Issue 10(2018)
- Issue Display:
- Volume 73, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 73
- Issue:
- 10
- Issue Sort Value:
- 2018-0073-0010-0000
- Page Start:
- 907.e1
- Page End:
- 907.e7
- Publication Date:
- 2018-10
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2018.07.100 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7257.xml