CFD (computational fluid dynamics) investigation on Nusselt number and friction factor of solar air heater duct roughened with non-uniform cross-section transverse rib. (1st May 2015)
- Record Type:
- Journal Article
- Title:
- CFD (computational fluid dynamics) investigation on Nusselt number and friction factor of solar air heater duct roughened with non-uniform cross-section transverse rib. (1st May 2015)
- Main Title:
- CFD (computational fluid dynamics) investigation on Nusselt number and friction factor of solar air heater duct roughened with non-uniform cross-section transverse rib
- Authors:
- Singh, Sukhmeet
Singh, Bikramjit
Hans, V.S.
Gill, R.S. - Abstract:
- Abstract: A 3-dimensional CFD (computational fluid dynamics) investigation has been carried out to study the heat transfer and friction characteristics of solar air heater duct roughened with periodic transverse rib. The selected rib roughness is a new concept; it has non-uniform cross-section in the form of saw-tooth. For comparison, transverse ribs with uniform cross-section of circular, square and trapezoidal have also been investigated. The Nusselt number and friction factor have been determined for Reynolds number range of 3000–15, 000. The k-ε turbulence model was selected for analysis. The non-uniform cross-section saw-tooth rib was found to result in higher Nusselt number than uniform cross-section ribs for Reynolds number above 7000 due to reduced low heat transfer area downstream of the rib caused by disruption in re-circulations. The maximum enhancement in Nusselt number for duct roughened with saw-tooth rib and trapezoidal rib was 1.78 and 1.50 respectively. The friction factor was found to be lower for saw-tooth rib as compared to uniform cross-section ribs investigated. The maximum enhancement in friction factor for duct roughened with saw-tooth and trapezoidal rib was 2.49 and 3.58 respectively. Highlights: A transverse periodic rib based on a new concept, non-uniform cross-section rib, investigated using CFD. Non-uniform cross-section rib results in higher Nusselt number than uniform cross-section rib at higher Reynolds number. Non-uniform cross-section ribAbstract: A 3-dimensional CFD (computational fluid dynamics) investigation has been carried out to study the heat transfer and friction characteristics of solar air heater duct roughened with periodic transverse rib. The selected rib roughness is a new concept; it has non-uniform cross-section in the form of saw-tooth. For comparison, transverse ribs with uniform cross-section of circular, square and trapezoidal have also been investigated. The Nusselt number and friction factor have been determined for Reynolds number range of 3000–15, 000. The k-ε turbulence model was selected for analysis. The non-uniform cross-section saw-tooth rib was found to result in higher Nusselt number than uniform cross-section ribs for Reynolds number above 7000 due to reduced low heat transfer area downstream of the rib caused by disruption in re-circulations. The maximum enhancement in Nusselt number for duct roughened with saw-tooth rib and trapezoidal rib was 1.78 and 1.50 respectively. The friction factor was found to be lower for saw-tooth rib as compared to uniform cross-section ribs investigated. The maximum enhancement in friction factor for duct roughened with saw-tooth and trapezoidal rib was 2.49 and 3.58 respectively. Highlights: A transverse periodic rib based on a new concept, non-uniform cross-section rib, investigated using CFD. Non-uniform cross-section rib results in higher Nusselt number than uniform cross-section rib at higher Reynolds number. Non-uniform cross-section rib results in lower friction factor than uniform cross-section rib. … (more)
- Is Part Of:
- Energy. Volume 84(2015)
- Journal:
- Energy
- Issue:
- Volume 84(2015)
- Issue Display:
- Volume 84, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 84
- Issue:
- 2015
- Issue Sort Value:
- 2015-0084-2015-0000
- Page Start:
- 509
- Page End:
- 517
- Publication Date:
- 2015-05-01
- Subjects:
- Nusselt number -- Friction factor -- Non-uniform rib -- Saw-tooth rib -- Periodic flow
Power resources -- Periodicals
Power (Mechanics) -- Periodicals
Energy consumption -- Periodicals
333.7905 - Journal URLs:
- http://www.elsevier.com/journals ↗
- DOI:
- 10.1016/j.energy.2015.03.015 ↗
- Languages:
- English
- ISSNs:
- 0360-5442
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.445000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7254.xml