On battery-less autonomous polygeneration microgrids: Investigation of the combined hybrid capacitors/hydrogen alternative. (February 2015)
- Record Type:
- Journal Article
- Title:
- On battery-less autonomous polygeneration microgrids: Investigation of the combined hybrid capacitors/hydrogen alternative. (February 2015)
- Main Title:
- On battery-less autonomous polygeneration microgrids: Investigation of the combined hybrid capacitors/hydrogen alternative
- Authors:
- Kyriakarakos, George
Piromalis, Dimitrios D.
Arvanitis, Konstantinos G.
Dounis, Anastasios I.
Papadakis, George - Abstract:
- Highlights: A battery-less autonomous polygeneration microgrid is technically feasible. Laboratory testing of hybrid capacitors. Investigation of hybrid capacitors utilization along with hydrogen subsystem. Abstract: The autonomous polygeneration microgrid topology aims to cover holistically the needs in remote areas as far as electrical power, potable water through desalination, fuel for transportation in the form of hydrogen, heating and cooling are concerned. Deep discharge lead acid batteries are mostly used in such systems, associated with specific disadvantages, both technical and environmental. This paper investigated the possibility of replacing the battery bank from a polygeneration microgrid with a hybrid capacitor bank and more intensive utilization of a hydrogen subsystem. Initially commercial hybrid capacitors were tested under laboratory conditions and based on the respective results a case study was performed. The optimized combination of hybrid capacitors and higher hydrogen usage was then investigated through simulations and compared to a polygeneration microgrid featuring deep discharge lead acid batteries. From the results it was clear that it is technically possible to exchange the battery bank with a hybrid capacitor bank and higher hydrogen utilization. From the economic point of view, the current cost of the hybrid capacitors and the hydrogen components is high which leads to higher overall cost in comparison with deep discharge lead acid batteries.Highlights: A battery-less autonomous polygeneration microgrid is technically feasible. Laboratory testing of hybrid capacitors. Investigation of hybrid capacitors utilization along with hydrogen subsystem. Abstract: The autonomous polygeneration microgrid topology aims to cover holistically the needs in remote areas as far as electrical power, potable water through desalination, fuel for transportation in the form of hydrogen, heating and cooling are concerned. Deep discharge lead acid batteries are mostly used in such systems, associated with specific disadvantages, both technical and environmental. This paper investigated the possibility of replacing the battery bank from a polygeneration microgrid with a hybrid capacitor bank and more intensive utilization of a hydrogen subsystem. Initially commercial hybrid capacitors were tested under laboratory conditions and based on the respective results a case study was performed. The optimized combination of hybrid capacitors and higher hydrogen usage was then investigated through simulations and compared to a polygeneration microgrid featuring deep discharge lead acid batteries. From the results it was clear that it is technically possible to exchange the battery bank with a hybrid capacitor bank and higher hydrogen utilization. From the economic point of view, the current cost of the hybrid capacitors and the hydrogen components is high which leads to higher overall cost in comparison with deep discharge lead acid batteries. Taking into account, though, the decreasing cost prospects and trends of both the hybrid capacitors and the hydrogen components it is expected that this approach will become economically competitive in a few years. … (more)
- Is Part Of:
- Energy conversion and management. Volume 91(2015)
- Journal:
- Energy conversion and management
- Issue:
- Volume 91(2015)
- Issue Display:
- Volume 91, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 91
- Issue:
- 2015
- Issue Sort Value:
- 2015-0091-2015-0000
- Page Start:
- 405
- Page End:
- 415
- Publication Date:
- 2015-02
- Subjects:
- APM autonomous polygeneration microgrid -- CF cost function -- FCM Fuzzy Cognitive Map -- FM Flow Matrix or Incidence Matrix of the Petri Net -- NPC Net Present Cost -- PSO Particle Swarm Optimization -- RO reverse osmosis
Hybrid capacitors -- Polygeneration -- Microgrid -- Hydrogen
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2014.12.027 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7236.xml