Involvement of Cu(II) in the electrocatalytic reduction of bromate on a disposable nano-copper oxide modified screen-printed carbon electrode: hair waving products as an example. (10th April 2015)
- Record Type:
- Journal Article
- Title:
- Involvement of Cu(II) in the electrocatalytic reduction of bromate on a disposable nano-copper oxide modified screen-printed carbon electrode: hair waving products as an example. (10th April 2015)
- Main Title:
- Involvement of Cu(II) in the electrocatalytic reduction of bromate on a disposable nano-copper oxide modified screen-printed carbon electrode: hair waving products as an example
- Authors:
- Chen, Pei-Yen
Yang, Hsueh-Hui
Huang, Chien-Chang
Chen, Yu-Hsuan
Shih, Ying - Abstract:
- Graphical abstract: Highlights: CuOSPCEs were prepared via electrodeposition of copper ions on bare SPCEs electrodes. The CuOSPCEs show an enhanced electrocatalytic activity toward bromate reduction. CuOSPE coupling with FIA demonstrates excellent analytical performance for bromate. High selectivity and sensitivity with low detection limit. Abstract: A disposable nano-copper oxide modified screen-printed carbon electrode (CuOSPCE) was developed as a quick and convenient method to identify the bromate content in hair waving products. The electrode was prepared via electrodeposition of copper ions on a bare screen-printed carbon electrode (SPCE). It was demonstrated that the nano-copper oxide on the SPCEs could significantly enhance the electrochemical reduction of bromate in weak acidic solutions. The analytical results indicate that CuOSPCE coupling with a flow injection analysis (FIA) system (CuOSPCE/FIA) is a sensitive method for the determination of the bromate. A wide linear range from 0.01 to 300 mg L −1 (66.27 to 1.99 × 10 6 nmol L −1 ) was observed, and a detection limit of 3.5 μg L −1 (23.19 nmol L −1 ) (DL, S/N = 3) was calculated. The results also indicated that both the sensitivity and the response time of CuOSPCE/FIA toward bromate were not affected by several anions. Furthermore, the CuOSPCE/FIA demonstrated extremely high recovery, ranging from 98.45% to 103.89%, as well as good accuracy compared to the results obtained by a standard iodometric method.
- Is Part Of:
- Electrochimica acta. Volume 161(2015)
- Journal:
- Electrochimica acta
- Issue:
- Volume 161(2015)
- Issue Display:
- Volume 161, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 161
- Issue:
- 2015
- Issue Sort Value:
- 2015-0161-2015-0000
- Page Start:
- 100
- Page End:
- 107
- Publication Date:
- 2015-04-10
- Subjects:
- copper -- bromate -- hair waving products -- screen-printed carbon electrode
Electrochemistry -- Periodicals
Electrochemistry, Industrial -- Periodicals
541.37 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00134686 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.electacta.2015.02.060 ↗
- Languages:
- English
- ISSNs:
- 0013-4686
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.950000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7253.xml