Assessment of image quality of a radiotherapy-specific hardware solution for PET/MRI in head and neck cancer patients. Issue 3 (September 2018)
- Record Type:
- Journal Article
- Title:
- Assessment of image quality of a radiotherapy-specific hardware solution for PET/MRI in head and neck cancer patients. Issue 3 (September 2018)
- Main Title:
- Assessment of image quality of a radiotherapy-specific hardware solution for PET/MRI in head and neck cancer patients
- Authors:
- Winter, René M.
Leibfarth, Sara
Schmidt, Holger
Zwirner, Kerstin
Mönnich, David
Welz, Stefan
Schwenzer, Nina F.
la Fougère, Christian
Nikolaou, Konstantin
Gatidis, Sergios
Zips, Daniel
Thorwarth, Daniela - Abstract:
- Abstract: Background and purpose: Functional PET/MRI has great potential to improve radiotherapy planning (RTP). However, data integration requires imaging with radiotherapy-specific patient positioning. Here, we investigated the feasibility and image quality of radiotherapy-customized PET/MRI in head-and-neck cancer (HNC) patients using a dedicated hardware setup. Material and methods: Ten HNC patients were examined with simultaneous PET/MRI before treatment, with radiotherapy and diagnostic scan setup, respectively. We tested feasibility of radiotherapy-specific patient positioning and compared the image quality between both setups by pairwise image analysis of 18 F-FDG-PET, T1/T2-weighted and diffusion-weighted MRI. For image quality assessment, similarity measures including average symmetric surface distance (ASSD) of PET and MR-based tumor contours, MR signal-to-noise ratio (SNR) and mean apparent diffusion coefficient (ADC) value were used. Results: PET/MRI in radiotherapy position was feasible – all patients were successfully examined. ASSD (median/range) of PET and MR contours was 0.6 (0.4–1.2) and 0.9 (0.5–1.3) mm, respectively. For T2-weighted MRI, a reduced SNR of −26.2% (−39.0–−11.7) was observed with radiotherapy setup. No significant difference in mean ADC was found. Conclusions: Simultaneous PET/MRI in HNC patients using radiotherapy positioning aids is clinically feasible. Though SNR was reduced, the image quality obtained with a radiotherapy setup meets RTPAbstract: Background and purpose: Functional PET/MRI has great potential to improve radiotherapy planning (RTP). However, data integration requires imaging with radiotherapy-specific patient positioning. Here, we investigated the feasibility and image quality of radiotherapy-customized PET/MRI in head-and-neck cancer (HNC) patients using a dedicated hardware setup. Material and methods: Ten HNC patients were examined with simultaneous PET/MRI before treatment, with radiotherapy and diagnostic scan setup, respectively. We tested feasibility of radiotherapy-specific patient positioning and compared the image quality between both setups by pairwise image analysis of 18 F-FDG-PET, T1/T2-weighted and diffusion-weighted MRI. For image quality assessment, similarity measures including average symmetric surface distance (ASSD) of PET and MR-based tumor contours, MR signal-to-noise ratio (SNR) and mean apparent diffusion coefficient (ADC) value were used. Results: PET/MRI in radiotherapy position was feasible – all patients were successfully examined. ASSD (median/range) of PET and MR contours was 0.6 (0.4–1.2) and 0.9 (0.5–1.3) mm, respectively. For T2-weighted MRI, a reduced SNR of −26.2% (−39.0–−11.7) was observed with radiotherapy setup. No significant difference in mean ADC was found. Conclusions: Simultaneous PET/MRI in HNC patients using radiotherapy positioning aids is clinically feasible. Though SNR was reduced, the image quality obtained with a radiotherapy setup meets RTP requirements and the data can thus be used for personalized RTP. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 128:Issue 3(2018)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 128:Issue 3(2018)
- Issue Display:
- Volume 128, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 128
- Issue:
- 3
- Issue Sort Value:
- 2018-0128-0003-0000
- Page Start:
- 485
- Page End:
- 491
- Publication Date:
- 2018-09
- Subjects:
- PET/MRI -- Functional imaging -- Radiotherapy -- Treatment planning -- Patient immobilization -- Head and neck
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2018.04.018 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7259.xml