Introduction of optically stimulated luminescence based postal audits for radiation protection level dosimetry at Secondary Standard Dosimetry Laboratories. (November 2017)
- Record Type:
- Journal Article
- Title:
- Introduction of optically stimulated luminescence based postal audits for radiation protection level dosimetry at Secondary Standard Dosimetry Laboratories. (November 2017)
- Main Title:
- Introduction of optically stimulated luminescence based postal audits for radiation protection level dosimetry at Secondary Standard Dosimetry Laboratories
- Authors:
- Bokulic, Tomislav
Wesolowska, Paulina
Cole, Andrew
Csete, Istvan
Izewska, Joanna
Kazantsev, Pavel
Meghzifene, Ahmed - Abstract:
- Abstract: The IAEA has introduced an Optically Stimulated Luminescence Dosimetry (OSLD) system to conduct postal audits to Secondary Standard Dosimetry Laboratories (SSDLs) for radiation protection level. The audit independently checks 137 Cs radiation protection air kerma calibrations provided by the SSLDs. The OSLD system has replaced the previously used TLD based audit for radiation protection. The OSLD system used in the audit consists of nanoDot dosimeters and MicroSTARii reader (Landauer, IL, USA). Prior to introducing the audit service, an extensive commissioning process quantified the dosimeter reading reproducibility, signal depletion and fading, linearity of response to air kerma, individual sensitivities of OSLDs and optical annealing procedure for the dosimeters. In an audit run, the participating SSLDs are supplied with two dosimeter sets consisting of two lightweight holders each preloaded with two OSLDs. The participants are asked to irradiate them with 5 mGy air kerma free in air, following their standard laboratory procedures. The OSLDs returned to the IAEA are evaluated by the IAEA Dosimetry Laboratory. The OSLDs demonstrated acceptable reading reproducibility of 1.75% and a signal depletion of 0.25% per readout. The OSLDs signal fading resulted in a signal decrease of 2.1% in the period from eight days to over 160 days post irradiation. A relative expanded (k = 2) uncertainty of the OSLD determined air kerma was estimated to 3.08%. In two audit runs inAbstract: The IAEA has introduced an Optically Stimulated Luminescence Dosimetry (OSLD) system to conduct postal audits to Secondary Standard Dosimetry Laboratories (SSDLs) for radiation protection level. The audit independently checks 137 Cs radiation protection air kerma calibrations provided by the SSLDs. The OSLD system has replaced the previously used TLD based audit for radiation protection. The OSLD system used in the audit consists of nanoDot dosimeters and MicroSTARii reader (Landauer, IL, USA). Prior to introducing the audit service, an extensive commissioning process quantified the dosimeter reading reproducibility, signal depletion and fading, linearity of response to air kerma, individual sensitivities of OSLDs and optical annealing procedure for the dosimeters. In an audit run, the participating SSLDs are supplied with two dosimeter sets consisting of two lightweight holders each preloaded with two OSLDs. The participants are asked to irradiate them with 5 mGy air kerma free in air, following their standard laboratory procedures. The OSLDs returned to the IAEA are evaluated by the IAEA Dosimetry Laboratory. The OSLDs demonstrated acceptable reading reproducibility of 1.75% and a signal depletion of 0.25% per readout. The OSLDs signal fading resulted in a signal decrease of 2.1% in the period from eight days to over 160 days post irradiation. A relative expanded (k = 2) uncertainty of the OSLD determined air kerma was estimated to 3.08%. In two audit runs in 2015–2016, 29 SSDLs participated. The average ratio of the air kerma measured by the IAEA to the air kerma stated by the SSDL was 0.998 and the standard deviation of the distribution of results was 1.8%. All participants except one had results within the acceptance limits of ±7%. One laboratory with the result outside the acceptance limit was invited to a follow-up procedure with the aim to resolve the discrepancy. Highlights: OSL dosimeters were commissioned for the audit system at radiation protection level. OSLDs showed good reproducibility and low signal fading. OSLD based audits for radiation protection calibrations have been successfully established. … (more)
- Is Part Of:
- Radiation measurements. Volume 106(2017:Nov.)
- Journal:
- Radiation measurements
- Issue:
- Volume 106(2017:Nov.)
- Issue Display:
- Volume 106 (2017)
- Year:
- 2017
- Volume:
- 106
- Issue Sort Value:
- 2017-0106-0000-0000
- Page Start:
- 546
- Page End:
- 551
- Publication Date:
- 2017-11
- Subjects:
- Optically stimulated luminescence dosimetry -- Remote audit -- Radiation protection -- Air kerma
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2017.04.006 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7236.xml