In vivo multimodal magnetic particle imaging (MPI) with tailored magneto/optical contrast agents. (June 2015)
- Record Type:
- Journal Article
- Title:
- In vivo multimodal magnetic particle imaging (MPI) with tailored magneto/optical contrast agents. (June 2015)
- Main Title:
- In vivo multimodal magnetic particle imaging (MPI) with tailored magneto/optical contrast agents
- Authors:
- Arami, Hamed
Khandhar, Amit P.
Tomitaka, Asahi
Yu, Elaine
Goodwill, Patrick W.
Conolly, Steven M.
Krishnan, Kannan M. - Abstract:
- Abstract: Magnetic Particle Imaging (MPI) is a novel non-invasive biomedical imaging modality that uses safe magnetite nanoparticles as tracers. Controlled synthesis of iron oxide nanoparticles (NPs) with tuned size-dependent magnetic relaxation properties is critical for the development of MPI. Additional functionalization of these NPs for other imaging modalities ( e.g . MRI and fluorescent imaging) would accelerate screening of the MPI tracers based on their in vitro and in vivo performance in pre-clinical trials. Here, we conjugated two different types of poly-ethylene-glycols (NH2 -PEG-NH2 and NH2 -PEG-FMOC) to monodisperse carboxylated 19.7 nm NPs by amide bonding. Further, we labeled these NPs with Cy5.5 near infra-red fluorescent (NIRF) molecules. Bi-functional PEG (NH2 -PEG-NH2 ) resulted in larger hydrodynamic size (∼98 nm vs. ∼43 nm) of the tracers, due to inter-particle crosslinking. Formation of such clusters impacted the multimodal imaging performance and pharmacokinetics of these tracers. We found that MPI signal intensity of the tracers in blood depends on their plasmatic clearance pharmacokinetics. Whole body mice MPI/MRI/NIRF, used to study the biodistribution of the injected NPs, showed primary distribution in liver and spleen. Biodistribution of tracers and their clearance pathway was further confirmed by MPI and NIRF signals from the excised organs where the Cy5.5 labeling enabled detailed anatomical mapping of the tracers.in tissue sections. TheseAbstract: Magnetic Particle Imaging (MPI) is a novel non-invasive biomedical imaging modality that uses safe magnetite nanoparticles as tracers. Controlled synthesis of iron oxide nanoparticles (NPs) with tuned size-dependent magnetic relaxation properties is critical for the development of MPI. Additional functionalization of these NPs for other imaging modalities ( e.g . MRI and fluorescent imaging) would accelerate screening of the MPI tracers based on their in vitro and in vivo performance in pre-clinical trials. Here, we conjugated two different types of poly-ethylene-glycols (NH2 -PEG-NH2 and NH2 -PEG-FMOC) to monodisperse carboxylated 19.7 nm NPs by amide bonding. Further, we labeled these NPs with Cy5.5 near infra-red fluorescent (NIRF) molecules. Bi-functional PEG (NH2 -PEG-NH2 ) resulted in larger hydrodynamic size (∼98 nm vs. ∼43 nm) of the tracers, due to inter-particle crosslinking. Formation of such clusters impacted the multimodal imaging performance and pharmacokinetics of these tracers. We found that MPI signal intensity of the tracers in blood depends on their plasmatic clearance pharmacokinetics. Whole body mice MPI/MRI/NIRF, used to study the biodistribution of the injected NPs, showed primary distribution in liver and spleen. Biodistribution of tracers and their clearance pathway was further confirmed by MPI and NIRF signals from the excised organs where the Cy5.5 labeling enabled detailed anatomical mapping of the tracers.in tissue sections. These multimodal MPI tracers, combining the strengths of each imaging modality ( e.g . resolution, tracer sensitivity and clinical use feasibility) pave the way for various in vitro and in vivo MPI applications. … (more)
- Is Part Of:
- Biomaterials. Volume 52(2015)
- Journal:
- Biomaterials
- Issue:
- Volume 52(2015)
- Issue Display:
- Volume 52, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 52
- Issue:
- 2015
- Issue Sort Value:
- 2015-0052-2015-0000
- Page Start:
- 251
- Page End:
- 261
- Publication Date:
- 2015-06
- Subjects:
- Magnetic particle imaging -- Biodistribution and pharmacokinetics -- Multimodal contrast agents -- Magnetic nanoparticles, Magnetic Resonance Imaging
Biomedical materials -- Periodicals
Biocompatible Materials -- Periodicals
Biomatériaux -- Périodiques
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01429612 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01429612 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01429612 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biomaterials.2015.02.040 ↗
- Languages:
- English
- ISSNs:
- 0142-9612
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.715000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7261.xml