Vector Flow Imaging Compared with Conventional Doppler Ultrasound and Thermodilution for Estimation of Blood Flow in the Ascending Aorta. (January 2017)
- Record Type:
- Journal Article
- Title:
- Vector Flow Imaging Compared with Conventional Doppler Ultrasound and Thermodilution for Estimation of Blood Flow in the Ascending Aorta. (January 2017)
- Main Title:
- Vector Flow Imaging Compared with Conventional Doppler Ultrasound and Thermodilution for Estimation of Blood Flow in the Ascending Aorta
- Authors:
- Hansen, Kristoffer Lindskov
Møller-Sørensen, Hasse
Kjaergaard, Jesper
Jensen, Maiken Brit
Lund, Jens Teglgaard
Pedersen, Mads Møller
Olesen, Jacob Bjerring
Jensen, Jørgen Arendt
Nielsen, Michael Bachmann - Abstract:
- Transverse oscillation (TO) is a real-time ultrasound vector flow method implemented on a commercial scanner. The TO setup was examined on a flowrig with constant and pulsatile flow. Subsequently, 25 patients undergoing cardiac bypass surgery were scanned intraoperatively with TO on the ascending aorta and compared to transesophageal echocardiography (TEE) and pulmonary artery catheter thermodilution (PACTD). On the flowrig, TO had a precision of 5.5%, 9.4% and 14.7%, a percentage error of 18.2%, 14.6% and 40.7%, and a mean bias of 0.4 cm/s, 36.8 ml/min and 32.4 ml/min for velocity and flow rate (constant and pulsatile) estimation. The correlation coefficients for all flowrig evaluations were 0.99 indicating systematic bias. After bias correction, the percentage error was reduced to 11.5%, 12.6% and 15.9% for velocity and flow rate (constant and pulsatile) estimation. In the in vivo setup, TO, TEE, and PACTD had a precision of 21.9%, 13.7%, and 12.0%. TO compared with TEE and PACTD had a mean bias of 12.6 cm/s and −0.08 l/min, and a percentage error of 23.4%, and 36.7%, respectively. The percentage error was reduced to 22.9% for the TEE comparison, but increased to 43.8% for the PACTD comparison, after correction for the systematic bias found in the flowrig. TO is a reliable and precise method for velocity and flow rate estimation on a flowrig. However, TO with the present setup, is not interchangeable with PACTD for cardiac volume flow estimation, but is a reliable andTransverse oscillation (TO) is a real-time ultrasound vector flow method implemented on a commercial scanner. The TO setup was examined on a flowrig with constant and pulsatile flow. Subsequently, 25 patients undergoing cardiac bypass surgery were scanned intraoperatively with TO on the ascending aorta and compared to transesophageal echocardiography (TEE) and pulmonary artery catheter thermodilution (PACTD). On the flowrig, TO had a precision of 5.5%, 9.4% and 14.7%, a percentage error of 18.2%, 14.6% and 40.7%, and a mean bias of 0.4 cm/s, 36.8 ml/min and 32.4 ml/min for velocity and flow rate (constant and pulsatile) estimation. The correlation coefficients for all flowrig evaluations were 0.99 indicating systematic bias. After bias correction, the percentage error was reduced to 11.5%, 12.6% and 15.9% for velocity and flow rate (constant and pulsatile) estimation. In the in vivo setup, TO, TEE, and PACTD had a precision of 21.9%, 13.7%, and 12.0%. TO compared with TEE and PACTD had a mean bias of 12.6 cm/s and −0.08 l/min, and a percentage error of 23.4%, and 36.7%, respectively. The percentage error was reduced to 22.9% for the TEE comparison, but increased to 43.8% for the PACTD comparison, after correction for the systematic bias found in the flowrig. TO is a reliable and precise method for velocity and flow rate estimation on a flowrig. However, TO with the present setup, is not interchangeable with PACTD for cardiac volume flow estimation, but is a reliable and precise angle-independent ultrasound alternative for velocity estimation of cardiac flow. … (more)
- Is Part Of:
- Ultrasonic imaging. Volume 39:Number 1(2017)
- Journal:
- Ultrasonic imaging
- Issue:
- Volume 39:Number 1(2017)
- Issue Display:
- Volume 39, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2017-0039-0001-0000
- Page Start:
- 3
- Page End:
- 18
- Publication Date:
- 2017-01
- Subjects:
- vector flow imaging -- transverse oscillation -- flowrig -- intraoperative cardiac ultrasound -- ascending aorta
Diagnostic ultrasonic imaging -- Methodology -- Periodicals
Ultrasonic testing -- Periodicals
Ultrasonic imaging -- Periodicals
Ultrasonography -- Periodicals
Échographie -- Méthodologie -- Périodiques
Essais par ultrasons -- Périodiques
Imagerie ultrasonore -- Périodiques
616.07543 - Journal URLs:
- http://uix.sagepub.com/ ↗
http://www.sciencedirect.com/science/journal/01617346 ↗
http://www.sagepublications.com/ ↗
http://www.idealibrary.com ↗ - DOI:
- 10.1177/0161734615620137 ↗
- Languages:
- English
- ISSNs:
- 0161-7346
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7241.xml