A simple method of bronchial occlusion with silicone spigots (Endobronchial Watanabe Spigot; EWS®) using a curette. (December 2016)
- Record Type:
- Journal Article
- Title:
- A simple method of bronchial occlusion with silicone spigots (Endobronchial Watanabe Spigot; EWS®) using a curette. (December 2016)
- Main Title:
- A simple method of bronchial occlusion with silicone spigots (Endobronchial Watanabe Spigot; EWS®) using a curette
- Authors:
- Morikawa, Sayako
Okamura, Takuya
Minezawa, Tomoyuki
Goto, Yasuhiro
Hayashi, Masamichi
Yamaguchi, Teppei
Isogai, Sumito
Mieno, Yuki
Yamamoto, Naoki
Uozu, Sakurako
Nakanishi, Toru
Okazawa, Mitsushi
Imaizumi, Kazuyoshi - Abstract:
- Background: Bronchial occlusion with an Endobronchial Watanabe Spigot (EWS) has been shown to be useful in managing prolonged bronchopleural fistulas and intractable hemoptysis. EWS bronchial occlusion using a curette is less technically demanding. This retrospective study evaluated the clinical utility and simplicity of this method. Methods: A total of 18 consecutive patients (15 men, 3 women, aged 47–85 years) who underwent bronchial occlusion using an EWS from April 2012 to August 2014 were evaluated. The method involves sticking the tip of a curette into an EWS to the first joint, allowing it to be turned in any direction or at any angle. The time required to occlude the target bronchus was measured on routinely recorded digital videos. Other parameters evaluated included success rates, complications, and clinical outcomes. Results: Of the 18 patients, 11 underwent bronchial occlusion for intractable pneumothorax, 5 for postoperative bronchopleural fistula, two for intractable empyema, and one for hemoptysis. Each patient required 1–7 EWSs (median 4). Target bronchi included the right upper ( n = 8), left upper ( n = 5), right lower ( n = 2), left lower ( n = 2), and right middle ( n = 1) bronchi. The success rate of EWS insertion into the target bronchus was 100%. Time per EWS occlusion ranged from 65–528 sec (median 158.5 sec). Of the 62 insertions, 36 (58.1%) were completed within 3 min, and 58 (93.5%) within 5 min. Successful outcomes were observed in 15 (83.3%) ofBackground: Bronchial occlusion with an Endobronchial Watanabe Spigot (EWS) has been shown to be useful in managing prolonged bronchopleural fistulas and intractable hemoptysis. EWS bronchial occlusion using a curette is less technically demanding. This retrospective study evaluated the clinical utility and simplicity of this method. Methods: A total of 18 consecutive patients (15 men, 3 women, aged 47–85 years) who underwent bronchial occlusion using an EWS from April 2012 to August 2014 were evaluated. The method involves sticking the tip of a curette into an EWS to the first joint, allowing it to be turned in any direction or at any angle. The time required to occlude the target bronchus was measured on routinely recorded digital videos. Other parameters evaluated included success rates, complications, and clinical outcomes. Results: Of the 18 patients, 11 underwent bronchial occlusion for intractable pneumothorax, 5 for postoperative bronchopleural fistula, two for intractable empyema, and one for hemoptysis. Each patient required 1–7 EWSs (median 4). Target bronchi included the right upper ( n = 8), left upper ( n = 5), right lower ( n = 2), left lower ( n = 2), and right middle ( n = 1) bronchi. The success rate of EWS insertion into the target bronchus was 100%. Time per EWS occlusion ranged from 65–528 sec (median 158.5 sec). Of the 62 insertions, 36 (58.1%) were completed within 3 min, and 58 (93.5%) within 5 min. Successful outcomes were observed in 15 (83.3%) of the 18 patients. Conclusions: EWS bronchial occlusion using a curette is a simple method for managing intractable bronchopleural fistulas in daily clinical settings. … (more)
- Is Part Of:
- Therapeutic advances in respiratory disease. Volume 10:Number 6(2016:Dec.)
- Journal:
- Therapeutic advances in respiratory disease
- Issue:
- Volume 10:Number 6(2016:Dec.)
- Issue Display:
- Volume 10, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 6
- Issue Sort Value:
- 2016-0010-0006-0000
- Page Start:
- 518
- Page End:
- 524
- Publication Date:
- 2016-12
- Subjects:
- bronchial occlusion -- bronchopleural fistula -- bronchoscopy -- curette -- Endobronchial Watanabe Spigot
Respiratory organs -- Diseases -- Periodicals
Respiratory agents -- Periodicals
Pulmonary pharmacology -- Periodicals
Respiratory Tract Diseases -- Periodicals
Respiratory System Agents -- therapeutic use -- Periodicals
Respiratory Tract Diseases -- drug therapy -- Periodicals
Lung Diseases -- drug therapy -- Periodicals
Appareil respiratoire -- Maladies -- Traitement -- Périodiques
Agents respiratoires -- Périodiques
Pharmacologie pulmonaire -- Périodiques
616.2005 - Journal URLs:
- http://tar.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1753465816664862 ↗
- Languages:
- English
- ISSNs:
- 1753-4658
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7224.xml