Impact of cytochrome P450 2C19 loss-of-function polymorphism on intra-stent thrombi and lesion outcome after everolimus-eluting stent implantation compared to that after first-generation drug-eluting stent implantation. (20th January 2015)
- Record Type:
- Journal Article
- Title:
- Impact of cytochrome P450 2C19 loss-of-function polymorphism on intra-stent thrombi and lesion outcome after everolimus-eluting stent implantation compared to that after first-generation drug-eluting stent implantation. (20th January 2015)
- Main Title:
- Impact of cytochrome P450 2C19 loss-of-function polymorphism on intra-stent thrombi and lesion outcome after everolimus-eluting stent implantation compared to that after first-generation drug-eluting stent implantation
- Authors:
- Konishi, Akihide
Shinke, Toshiro
Otake, Hiromasa
Nishio, Ryo
Sawada, Takahiro
Takaya, Tomofumi
Nakagawa, Masayuki
Osue, Tsuyoshi
Taniguchi, Yu
Iwasaki, Masamichi
Kinutani, Hiroto
Masaru, Kuroda
Takahashi, Hachidai
Terashita, Daisuke
Shite, Junya
Hirata, Ken-ichi - Abstract:
- Abstract: Background: The contribution of clopidogrel response due to cytochrome P450 (CYP) 2C19 loss-of-function polymorphism after drug-eluting stent (DES) implantation is unclear. Methods: A total of 196 patients who had undergone optical coherence tomography (OCT) at 8 months following first-generation DES (120 lesions) and current-generation everolimus-eluting stent (EES) implantation (127 lesions) were enrolled. Patients were divided into 3 groups by CYP2C19 polymorphism: extensive metabolizers (EMs), intermediate metabolizers (IMs), and poor metabolizers (PMs). OCT findings were compared among the 3 groups. Responsiveness to clopidogrel was assessed by VerifyNow platelet reactivity unit (PRU). Results: The incidence of intra-stent thrombi was significantly higher after first-generation DES implantation compared with EES implantation (35% vs 13%, respectively; p = 0.0001). In the first-generation DES group, the incidence of intra-stent thrombi significantly increased among EMs, IMs, and PMs (21% vs 36% vs 63%, respectively; p = 0.007), while there was no significant difference among the 3 groups after EES implantation (10% vs 13% vs 20%, respectively; p = 0.55). The PRU significantly increased among EMs, IMs, and PMs in each stent group. In multivariate analyses, although PMs had a 3-fold higher risk of thrombi formation compared with non-PMs after first-generation DES implantation, there were no significant differences in thrombi formation between the 2 groups afterAbstract: Background: The contribution of clopidogrel response due to cytochrome P450 (CYP) 2C19 loss-of-function polymorphism after drug-eluting stent (DES) implantation is unclear. Methods: A total of 196 patients who had undergone optical coherence tomography (OCT) at 8 months following first-generation DES (120 lesions) and current-generation everolimus-eluting stent (EES) implantation (127 lesions) were enrolled. Patients were divided into 3 groups by CYP2C19 polymorphism: extensive metabolizers (EMs), intermediate metabolizers (IMs), and poor metabolizers (PMs). OCT findings were compared among the 3 groups. Responsiveness to clopidogrel was assessed by VerifyNow platelet reactivity unit (PRU). Results: The incidence of intra-stent thrombi was significantly higher after first-generation DES implantation compared with EES implantation (35% vs 13%, respectively; p = 0.0001). In the first-generation DES group, the incidence of intra-stent thrombi significantly increased among EMs, IMs, and PMs (21% vs 36% vs 63%, respectively; p = 0.007), while there was no significant difference among the 3 groups after EES implantation (10% vs 13% vs 20%, respectively; p = 0.55). The PRU significantly increased among EMs, IMs, and PMs in each stent group. In multivariate analyses, although PMs had a 3-fold higher risk of thrombi formation compared with non-PMs after first-generation DES implantation, there were no significant differences in thrombi formation between the 2 groups after EES implantation. The optimal PRU cutoff values for the prediction of intra-stent thrombi with first-generation DES and EES were 234 and 256, respectively. Conclusion: CYP2C19 loss-of-function polymorphism is associated with a higher incidence of intra-stent thrombi after first-generation DES implantation, while the impact is attenuated following EES implantation. … (more)
- Is Part Of:
- International journal of cardiology. Volume 179(2015)
- Journal:
- International journal of cardiology
- Issue:
- Volume 179(2015)
- Issue Display:
- Volume 179, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 179
- Issue:
- 2015
- Issue Sort Value:
- 2015-0179-2015-0000
- Page Start:
- 476
- Page End:
- 483
- Publication Date:
- 2015-01-20
- Subjects:
- CYP2C19 -- Thrombi -- Everolimus eluting stent -- Optical coherence tomography
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2014.11.068 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7222.xml