Validation of a low-cost laser scanner device for the assessment of three-dimensional facial anatomy in living subjects. Issue 9 (September 2018)
- Record Type:
- Journal Article
- Title:
- Validation of a low-cost laser scanner device for the assessment of three-dimensional facial anatomy in living subjects. Issue 9 (September 2018)
- Main Title:
- Validation of a low-cost laser scanner device for the assessment of three-dimensional facial anatomy in living subjects
- Authors:
- Gibelli, Daniele
Pucciarelli, Valentina
Caplova, Zuzana
Cappella, Annalisa
Dolci, Claudia
Cattaneo, Cristina
Sforza, Chiarella - Abstract:
- Abstract: The present study compared the reliability of a low-cost laser scanner device to an already-validated stereophotogrammetric instrument. Fifty volunteers underwent duplicate facial scans through laser scanner and stereophotogrammetry. Intra- and inter-instrument reproducibility of linear distances, angles, facial surface area and volume was verified through the Bland–Altman test and calculation of absolute (TEM) and relative (rTEM) technical errors of measurement; rTEM was then classified as follows: <1% excellent; 1–3.9% very good; 4–6.9% good; 7–9.9% moderate; >10% poor. The scans performed through different devices were registered and superimposed to calculate the root mean square (RMS) (point-to-point) distance between the two surfaces. The same protocol was applied to a mannequin head. In inter-instruments comparison, 12/26 measurements showed a "good" rTEM; 5 were "very good". In intra-instrument comparison, most performances worsened, with only 10 of 26 measurements classified as "good" and "very good". All the measurements made on mannequin scans were at least "good", and 14/26 were "very good". Surface area was "very good" only in intra-instrument comparison; conversely, volumes were poorly repeatable for all the comparisons. On average, RMS point-to-point distances were 0.65 mm (inter-devices comparison), 0.56 mm (mannequin scans), 0.42 mm (intra-device comparison). In conclusion, the low-cost laser scan device can be reliably applied to inanimate objects,Abstract: The present study compared the reliability of a low-cost laser scanner device to an already-validated stereophotogrammetric instrument. Fifty volunteers underwent duplicate facial scans through laser scanner and stereophotogrammetry. Intra- and inter-instrument reproducibility of linear distances, angles, facial surface area and volume was verified through the Bland–Altman test and calculation of absolute (TEM) and relative (rTEM) technical errors of measurement; rTEM was then classified as follows: <1% excellent; 1–3.9% very good; 4–6.9% good; 7–9.9% moderate; >10% poor. The scans performed through different devices were registered and superimposed to calculate the root mean square (RMS) (point-to-point) distance between the two surfaces. The same protocol was applied to a mannequin head. In inter-instruments comparison, 12/26 measurements showed a "good" rTEM; 5 were "very good". In intra-instrument comparison, most performances worsened, with only 10 of 26 measurements classified as "good" and "very good". All the measurements made on mannequin scans were at least "good", and 14/26 were "very good". Surface area was "very good" only in intra-instrument comparison; conversely, volumes were poorly repeatable for all the comparisons. On average, RMS point-to-point distances were 0.65 mm (inter-devices comparison), 0.56 mm (mannequin scans), 0.42 mm (intra-device comparison). In conclusion, the low-cost laser scan device can be reliably applied to inanimate objects, but does not meet the standards for three-dimensional facial acquisition on living persons. … (more)
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 46:Issue 9(2018)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 46:Issue 9(2018)
- Issue Display:
- Volume 46, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 9
- Issue Sort Value:
- 2018-0046-0009-0000
- Page Start:
- 1493
- Page End:
- 1499
- Publication Date:
- 2018-09
- Subjects:
- Facial anatomy -- Low-cost laser scanner -- Stereophotogrammetry -- RMS (root mean square)
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2018.06.009 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7207.xml