Mechanical chest compressions improved aspects of CPR in the LINC trial. (June 2015)
- Record Type:
- Journal Article
- Title:
- Mechanical chest compressions improved aspects of CPR in the LINC trial. (June 2015)
- Main Title:
- Mechanical chest compressions improved aspects of CPR in the LINC trial
- Authors:
- Esibov, Alexander
Banville, Isabelle
Chapman, Fred W.
Boomars, René
Box, Martyn
Rubertsson, Sten - Abstract:
- Abstract: Aim: We studied resuscitation process metrics in patients with out-of-hospital cardiac arrest enrolled in a randomized trial comparing one protocol designed to best use a mechanical CPR device, with another based on the 2005 European Resuscitation Council guidelines for manual CPR. Methods: We analyzed clinical data, ECG signals, and transthoracic impedance signals for a subset of the patients in the LUCAS in Cardiac Arrest (LINC) trial, including 124 patients randomized to mechanical and 82 to manual CPR. Chest compression fraction (CCF) was defined as the fraction of time during cardiac arrest that chest compressions were administered. Results: Patients in the mechanical CPR group had a higher CCF than those in the manual CPR group [0.84 (0.78, 0.91) vs. 0.79 (0.70, 0.86), p < 0.001]. The median duration of their pauses for defibrillation was also shorter [0 s (0, 6.0) vs. 10.0 s (7.0, 14.3), p < 0.001]. Compressions were interrupted for a median of 36.0 s to apply the compression device. There was no difference between groups in duration of the longest pause in compressions [32.5 s vs. 26.0 s, p = 0.24], number of compressions received per minute [86.5 vs. 88.3, p = 0.47], defibrillation success rate [73.2% vs. 81.0%, p = 0.15], or refibrillation rate [74% vs. 77%, p = 0.79]. Conclusions: A protocol using mechanical chest compression devices reduced interruptions in chest compressions, and enabled defibrillation during ongoing compressions, withoutAbstract: Aim: We studied resuscitation process metrics in patients with out-of-hospital cardiac arrest enrolled in a randomized trial comparing one protocol designed to best use a mechanical CPR device, with another based on the 2005 European Resuscitation Council guidelines for manual CPR. Methods: We analyzed clinical data, ECG signals, and transthoracic impedance signals for a subset of the patients in the LUCAS in Cardiac Arrest (LINC) trial, including 124 patients randomized to mechanical and 82 to manual CPR. Chest compression fraction (CCF) was defined as the fraction of time during cardiac arrest that chest compressions were administered. Results: Patients in the mechanical CPR group had a higher CCF than those in the manual CPR group [0.84 (0.78, 0.91) vs. 0.79 (0.70, 0.86), p < 0.001]. The median duration of their pauses for defibrillation was also shorter [0 s (0, 6.0) vs. 10.0 s (7.0, 14.3), p < 0.001]. Compressions were interrupted for a median of 36.0 s to apply the compression device. There was no difference between groups in duration of the longest pause in compressions [32.5 s vs. 26.0 s, p = 0.24], number of compressions received per minute [86.5 vs. 88.3, p = 0.47], defibrillation success rate [73.2% vs. 81.0%, p = 0.15], or refibrillation rate [74% vs. 77%, p = 0.79]. Conclusions: A protocol using mechanical chest compression devices reduced interruptions in chest compressions, and enabled defibrillation during ongoing compressions, without adversely affecting other resuscitation process metrics. Future emphasis on optimizing device deployment may be beneficial. … (more)
- Is Part Of:
- Resuscitation. Volume 91(2015)
- Journal:
- Resuscitation
- Issue:
- Volume 91(2015)
- Issue Display:
- Volume 91, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 91
- Issue:
- 2015
- Issue Sort Value:
- 2015-0091-2015-0000
- Page Start:
- 116
- Page End:
- 121
- Publication Date:
- 2015-06
- Subjects:
- Cardiopulmonary resuscitation (CPR) -- Mechanical CPR -- Out-of-hospital cardiac arrest (OHCA) -- Chest compression fraction -- Perishock pause -- Defibrillation
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2015.02.028 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7212.xml