A Simple and Easy Process for the Determination of Estimated Plasma Glucose Level in Patients Presenting to Hospital: An Example of Multicentric Data Mining. (December 2016)
- Record Type:
- Journal Article
- Title:
- A Simple and Easy Process for the Determination of Estimated Plasma Glucose Level in Patients Presenting to Hospital: An Example of Multicentric Data Mining. (December 2016)
- Main Title:
- A Simple and Easy Process for the Determination of Estimated Plasma Glucose Level in Patients Presenting to Hospital
- Authors:
- Serdar, Muhittin A.
Koldaş, Macit
Serteser, Mustafa
Akın, Okhan
Sonmez, Cigdem
Gülbahar, Ozlem
Akbıyık, Filiz
Ünsal, Ibrahim - Abstract:
- The aim of the present study was to determine the relation between the simultaneous fasting plasma glucose level and HbA1c in a large population of patients presenting to the hospital, based on various measurement methods available for HbA1c. HbA1c levels of 162, 210 patients presenting to various hospitals and laboratories were measured based on seven different systems, and at the same time, eAG levels were calculated based on HbA1c levels. The correlation coefficients ( r ) between serum plasma glucose and HbA1c levels were found to be 0.809, 0.774, 0.779, 0.817, 0.704, 0.796, and 0.747 in Bio-Rad Variant II, Tosoh G8, ADAMS A1c, Trinity Boronate Affinity, Chromsystems HPLC, Roche Tina-quant, and Abbott Architect, respectively. The concordance correlation coefficients between the eAG levels as calculated with the formulas provided in the text and the eAG levels as calculated according to NGSP directions (where eAG = (28.7*HbA1c) – 46.7) were found to be between 0.9339 and 0.9866. Despite the progress made for the standardization of HbA1c measurements, the relation between serum glucose and HbA1c still demonstrated certain discrepancies pertaining to the differences in measurement methodologies. As a conclusion, each laboratory could determine different eAG levels depending on the data originated by their individual analyzer.
- Is Part Of:
- Journal of laboratory automation. Volume 21:Number 6(2016:Dec.)
- Journal:
- Journal of laboratory automation
- Issue:
- Volume 21:Number 6(2016:Dec.)
- Issue Display:
- Volume 21, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 21
- Issue:
- 6
- Issue Sort Value:
- 2016-0021-0006-0000
- Page Start:
- 794
- Page End:
- 798
- Publication Date:
- 2016-12
- Subjects:
- data analysis -- informatics and software -- laboratory information management systems (LIMS) -- statistics
Medical laboratory technology -- Periodicals
Laboratories -- Equipment and supplies -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.075 - Journal URLs:
- http://journals.sagepub.com/home/jla ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/2211068215624468 ↗
- Languages:
- English
- ISSNs:
- 2211-0682
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.001000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7208.xml