Automated Patch Clamp Meets High-Throughput Screening: 384 Cells Recorded in Parallel on a Planar Patch Clamp Module. (December 2016)
- Record Type:
- Journal Article
- Title:
- Automated Patch Clamp Meets High-Throughput Screening: 384 Cells Recorded in Parallel on a Planar Patch Clamp Module. (December 2016)
- Main Title:
- Automated Patch Clamp Meets High-Throughput Screening
- Authors:
- Obergrussberger, Alison
Brüggemann, Andrea
Goetze, Tom A.
Rapedius, Markus
Haarmann, Claudia
Rinke, Ilka
Becker, Nadine
Oka, Takayuki
Ohtsuki, Atsushi
Stengel, Timo
Vogel, Marius
Steindl, Juergen
Mueller, Max
Stiehler, Johannes
George, Michael
Fertig, Niels - Abstract:
- We have developed an automated patch clamp module for high-throughput ion channel screening, recording from 384 cells simultaneously. The module is incorporated into a laboratory pipetting robot and uses a 384-channel pipettor head for application of cells and compounds. The module contains 384 amplifier channels for fully parallel recordings using a digital amplifier. Success rates for completed experiments (1- to 4-point concentration–response curves for cells satisfying defined quality control parameters) of greater than 85% have been routinely achieved with, for example, HEK, CHO, and RBL cell lines expressing hNaV 1.7, hERG, Kir2.1, GABA, or glutamate receptors. Pharmacology experiments are recorded and analyzed using specialized software, and the pharmacology of hNaV 1.7 and hERG is described. Fast external solution exchange rates of <50 ms are demonstrated using Kir2.1. Short exposure times are achieved by stacking the external solutions inside the pipette of the robot to minimize exposure of the ligand on the receptor. This ensures that ligand-gated ion channels, for example, GABA and glutamate described in this report, can be reproducibly recorded. Stem cell–derived cardiomyocytes have also been used with success rates of 52% for cells that have a seal resistance of >200 MΩ, and recordings of voltage-gated Na + and Ca 2+ are shown.
- Is Part Of:
- Journal of laboratory automation. Volume 21:Number 6(2016:Dec.)
- Journal:
- Journal of laboratory automation
- Issue:
- Volume 21:Number 6(2016:Dec.)
- Issue Display:
- Volume 21, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 21
- Issue:
- 6
- Issue Sort Value:
- 2016-0021-0006-0000
- Page Start:
- 779
- Page End:
- 793
- Publication Date:
- 2016-12
- Subjects:
- automated patch clamp -- ion channels -- high-throughput screening -- voltage-gated ion channels -- ligand-gated ion channels
Medical laboratory technology -- Periodicals
Laboratories -- Equipment and supplies -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.075 - Journal URLs:
- http://journals.sagepub.com/home/jla ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/2211068215623209 ↗
- Languages:
- English
- ISSNs:
- 2211-0682
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.001000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7208.xml