1B.09: ACCURACY OF HOME VERSUS AMBULATORY BLOOD PRESSURE MONITORING IN THE DIAGNOSIS OF WHITE-COAT AND MASKED HYPERTENSION. (June 2015)
- Record Type:
- Journal Article
- Title:
- 1B.09: ACCURACY OF HOME VERSUS AMBULATORY BLOOD PRESSURE MONITORING IN THE DIAGNOSIS OF WHITE-COAT AND MASKED HYPERTENSION. (June 2015)
- Main Title:
- 1B.09
- Authors:
- Kang, Y.
Li, Y.
Huang, Q.F.
Song, J.
Shan, X.L.
Dou, Y.
Xu, X.J.
Chen, S.H.
Wang, J.G. - Abstract:
- Abstract : Objective: We investigated accuracy of home blood pressure (BP) monitoring in the diagnosis of white-coat and masked hypertension in comparison with ambulatory BP monitoring. Design and method: Our study subjects were enrolled in the ongoing China Ambulatory and Home Blood Pressure Registry and underwent clinic, home and 24-hour ambulatory blood pressure measurements. The blood pressure threshold for hypertension diagnostic was 140mmHg and/or 90mmHg (systolic/diastolic) for clinic blood pressure, 130mmHg and/or 80mmHg for 24-hour ambulatory blood pressure and 135mmHg and/or 85mmHg for home blood pressure. We defined white-coat hypertension as an elevated clinic systolic/diastolic pressure and a normal 24-hour ambulatory or home systolic/diastolic pressure and masked hypertension as a normal clinic systolic/diastolic pressure and an elevated 24-hour ambulatory or home systolic/diastolic pressure. Results: In untreated subjects (n = 573), the prevalence of white-coat hypertension (13.1% vs. 19.9%), masked hypertension (17.8% vs. 13.1%) and sustained hypertension (46.4% vs. 39.6%) significantly (P < 0.02) differed between 24-hour ambulatory and home BP monitoring. In treated subjects (n = 1201), only the prevalence of masked hypertension differed significantly (18.7% vs.14.5%, P = 0.005). Regardless of the treatment status, home compared with 24-hour ambulatory BP had low sensitivity (range, 47%-74%) but high specificity (86%-94%) and accordingly low positiveAbstract : Objective: We investigated accuracy of home blood pressure (BP) monitoring in the diagnosis of white-coat and masked hypertension in comparison with ambulatory BP monitoring. Design and method: Our study subjects were enrolled in the ongoing China Ambulatory and Home Blood Pressure Registry and underwent clinic, home and 24-hour ambulatory blood pressure measurements. The blood pressure threshold for hypertension diagnostic was 140mmHg and/or 90mmHg (systolic/diastolic) for clinic blood pressure, 130mmHg and/or 80mmHg for 24-hour ambulatory blood pressure and 135mmHg and/or 85mmHg for home blood pressure. We defined white-coat hypertension as an elevated clinic systolic/diastolic pressure and a normal 24-hour ambulatory or home systolic/diastolic pressure and masked hypertension as a normal clinic systolic/diastolic pressure and an elevated 24-hour ambulatory or home systolic/diastolic pressure. Results: In untreated subjects (n = 573), the prevalence of white-coat hypertension (13.1% vs. 19.9%), masked hypertension (17.8% vs. 13.1%) and sustained hypertension (46.4% vs. 39.6%) significantly (P < 0.02) differed between 24-hour ambulatory and home BP monitoring. In treated subjects (n = 1201), only the prevalence of masked hypertension differed significantly (18.7% vs.14.5%, P = 0.005). Regardless of the treatment status, home compared with 24-hour ambulatory BP had low sensitivity (range, 47%-74%) but high specificity (86%-94%) and accordingly low positive (41%-87%) but high negative predictive values (80%-94%), and had moderate diagnostic agreement (82%-85%) and Kappa statistic (0.41–0.66). In untreated and treated subjects, age advancing was associated with a higher prevalence of white-coat hypertension and a lower prevalence of masked hypertension defined by 24-hour ambulatory (P < 0.04) but not home BP (P > 0.10). Conclusions: Home BP monitoring has high specificity but low sensitivity in the diagnosis of white-coat and masked hypertension, and may therefore behave as a complementary to, but not a replacement of, ambulatory BP monitoring. … (more)
- Is Part Of:
- Journal of hypertension. Volume 33(2015)Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 33(2015)Supplement 1
- Issue Display:
- Volume 33, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2015-0033-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-06
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000467371.88570.68 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7205.xml