Feasibility study of a novel multi-strip silicon detector for use in proton therapy range verification quality assurance. (November 2017)
- Record Type:
- Journal Article
- Title:
- Feasibility study of a novel multi-strip silicon detector for use in proton therapy range verification quality assurance. (November 2017)
- Main Title:
- Feasibility study of a novel multi-strip silicon detector for use in proton therapy range verification quality assurance
- Authors:
- Merchant, A.H.
Newall, M.
Guatelli, S.
Petasecca, M.
Lerch, M.
Perevertaylo, V.
Milluzzo, G.
Petringa, G.
Romano, F.
Cirrone, G.A.P.
Cuttone, G.
Jackson, M.
Rosenfeld, A.B. - Abstract:
- Abstract: The characterisation of a novel multi-strip silicon detector, the serial Dose Magnifying Glass, to incident 60 MeV mono-energetic proton beams, typical for ocular melanoma treatment, was performed by means of Geant4 simulations and experimental methods. Geant4 simulations were performed to determine the applicability and potential of the detector for proton beam range verification with high spatial resolution. Experimental characterisation was performed using the CATANA beam line to confirm the Monte Carlo feasibility study and determine the detector response to incident proton beams of 5 mm, 13 mm, 25 mm and 36 mm diameter, in addition to the detector response when PMMA slabs are positioned between the detector and the beam nozzle. Results indicate the suitability of the detector for proton beam range verification in proton therapy Quality Assurance. Highlights: A multi-strip silicon detector has been designed for proton range verification. Detector response has been experimentally characterised at the INFN CATANA facility. Geant4 studies have been performed to theoretically characterise the detector response.
- Is Part Of:
- Radiation measurements. Volume 106(2017:Nov.)
- Journal:
- Radiation measurements
- Issue:
- Volume 106(2017:Nov.)
- Issue Display:
- Volume 106 (2017)
- Year:
- 2017
- Volume:
- 106
- Issue Sort Value:
- 2017-0106-0000-0000
- Page Start:
- 378
- Page End:
- 384
- Publication Date:
- 2017-11
- Subjects:
- Particle therapy -- Proton range verification -- Multi-strip silicon detector -- Geant4 Monte Carlo
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2017.03.017 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7192.xml