Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart. Issue 4 (July 2015)
- Record Type:
- Journal Article
- Title:
- Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart. Issue 4 (July 2015)
- Main Title:
- Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart
- Authors:
- Karimov, Jamshid H.
Steffen, Robert J.
Byram, Nicole
Sunagawa, Gengo
Horvath, David
Cruz, Vincent
Golding, Leonard A. R.
Fukamachi, Kiyotaka
Moazami, Nader - Abstract:
- Abstract : Implantation of mechanical circulatory support devices is challenging, especially in patients with a small chest cavity. We evaluated how well the Cleveland Clinic continuous-flow total artificial heart (CFTAH) fit the anatomy of patients about to receive a heart transplant. A mock pump model of the CFTAH was rapid-prototyped using biocompatible materials. The model was brought to the operative table, and the direction, length, and angulation of the inflow/outflow ports and outflow conduits were evaluated after the recipient's ventricles had been resected. Thoracic cavity measurements were based on preoperative computed tomographic data. The CFTAH fit well in all five patients (height, 170 ± 9 cm; weight, 75 ± 24 kg). Body surface area was 1.9 ± 0.3 m 2 (range, 1.6–2.1 m 2 ). The required inflow and outflow port orientation of both the left and right housings appeared consistent with the current version of the CFTAH implanted in calves. The left outflow conduit remained straight, but the right outflow direction necessitated a 73 ± 22 degree angulation to prevent potential kinking when crossing over the connected left outflow. These data support the fact that our design achieves the proper anatomical relationship of the CFTAH to a patient's native vessels.
- Is Part Of:
- ASAIO journal. Volume 61:Issue 4(2015)
- Journal:
- ASAIO journal
- Issue:
- Volume 61:Issue 4(2015)
- Issue Display:
- Volume 61, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 61
- Issue:
- 4
- Issue Sort Value:
- 2015-0061-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- chest -- heart failure -- total artificial heart -- fitting study
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000219 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7181.xml