Correlation Between Home INR and Core Laboratory INR in Patients Supported with Continuous-Flow Left Ventricular Assist Devices. Issue 4 (July 2015)
- Record Type:
- Journal Article
- Title:
- Correlation Between Home INR and Core Laboratory INR in Patients Supported with Continuous-Flow Left Ventricular Assist Devices. Issue 4 (July 2015)
- Main Title:
- Correlation Between Home INR and Core Laboratory INR in Patients Supported with Continuous-Flow Left Ventricular Assist Devices
- Authors:
- Dionizovik-Dimanovski, Marija
Levin, Allison P.
Fried, Justin
Mody, Kanika P.
Simonich, Erica
Garan, Arthur Reshad
Yuzefpolskaya, Melana
Takayama, Hiroo
Naka, Yoshifumi
Colombo, Paolo C.
Kalesan, Bindu
Uriel, Nir
Jorde, Ulrich P. - Abstract:
- Abstract : It has been well established that patient self-testing (PST) of international normalized ratio (INR) using home monitoring devices increases the average therapeutic time and patient satisfaction. Long-term anticoagulation therapy with warfarin is used in patients with continuous-flow left ventricular assist device (CF-LVAD) to minimize the occurrence of thromboembolic events; however, PST devices have never been tested in patients with CF-LVADs. The purpose of this study was to determine the reliability of the PST device Alere INRatio 2 in patients supported with CF-LVADs. A correlation study was performed in 50 patients with CF-LVAD who were on stable warfarin therapy for a minimum of 3 weeks. Simultaneous INR values were determined from capillary whole blood samples using the Alere PST device and venous blood samples processed in the core laboratory at Columbia University Medical Center. There was a moderate correlation between the venous and the capillary INR values with a correlation coefficient of 0.83. The median difference between the methods was 0.39, with 44 of 50 patients recording higher INRs with Alere. Results remained unchanged after adjusting for use of amiodarone, abnormal hematocrit and liver enzymes, creatinine, and thyroid-stimulating hormone. Point of care testing with Alere correlates moderately well but consistently overestimates INR when compared with conventional laboratory testing in patients with CF-LVAD.
- Is Part Of:
- ASAIO journal. Volume 61:Issue 4(2015)
- Journal:
- ASAIO journal
- Issue:
- Volume 61:Issue 4(2015)
- Issue Display:
- Volume 61, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 61
- Issue:
- 4
- Issue Sort Value:
- 2015-0061-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- home INR -- LVAD INR -- LVAD home INR -- LVAD warfarin -- LVAD anticoagulation
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000229 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7181.xml