Comparison of Self-Expanding Stents With Distal Embolic Protection to Balloon-Expandable Stents Without a Protection Device in the Treatment of Symptomatic Vertebral Artery Origin Stenosis: A Prospective Randomized Trial. (June 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of Self-Expanding Stents With Distal Embolic Protection to Balloon-Expandable Stents Without a Protection Device in the Treatment of Symptomatic Vertebral Artery Origin Stenosis: A Prospective Randomized Trial. (June 2015)
- Main Title:
- Comparison of Self-Expanding Stents With Distal Embolic Protection to Balloon-Expandable Stents Without a Protection Device in the Treatment of Symptomatic Vertebral Artery Origin Stenosis
- Authors:
- Geng, Xiaokun
Hussain, Mohammed
Du, Huishan
Zhao, Liang
Chen, Jian
Su, Wei
Ma, Linlin
Gao, Zongen
Ding, Yuchuan
Ji, Xunming - Abstract:
- Purpose: To compare the angiographic and clinical outcomes of self-expanding stents (SES) with distal embolic protection devices (EPD) vs balloon-expandable stents (BES) without EPD in the treatment of symptomatic atherosclerotic vertebral artery ostial stenosis (VAOS).Methods: Between July 2011 and March 2013, a prospective randomized trial was conducted involving 127 patients (mean age 67.3±10.2 years; 94 men) with symptomatic VAOS randomly assigned to treatment with SES + EPD (Precise RX or RX Acculink stent + Spider FX EPD; n=61) or BES (Palmaz Blue or Resolute RX; n=66) without EPD. In-stent restenosis (ISR) >50% detected by duplex ultrasound was the primary endpoint. Technical success, clinical success, complications within 30 days, and signal intensity abnormalities on diffusion weighted imaging (DWI) after stenting were compared.Results: The 30-day technical success rate was 95.5% (63/66) for SES+EPD vs 100% (70/70) for BES without EPD (p=0.072). DWI at 24 hours poststenting showed 2 hyperintense lesions in 2 (3.3%) SES + EPD cases and 15 hyperintense lesions in 13 (18.6%) BES patients (p<0.01). At a mean 18-month follow-up, the clinical success rate was 93.9% (62/66) for the SES + EPD group vs 85.7% (60/70) for the BES group (p=0.115). The ISR was seen in 16/70 (22.9%) arteries in the BES group and 2/66 (3.1%) arteries in SES + EPD group (p<0.01). Target vessel revascularization was performed in 7 (10.0%) BES arteries vs none in the SES + EPD groupPurpose: To compare the angiographic and clinical outcomes of self-expanding stents (SES) with distal embolic protection devices (EPD) vs balloon-expandable stents (BES) without EPD in the treatment of symptomatic atherosclerotic vertebral artery ostial stenosis (VAOS).Methods: Between July 2011 and March 2013, a prospective randomized trial was conducted involving 127 patients (mean age 67.3±10.2 years; 94 men) with symptomatic VAOS randomly assigned to treatment with SES + EPD (Precise RX or RX Acculink stent + Spider FX EPD; n=61) or BES (Palmaz Blue or Resolute RX; n=66) without EPD. In-stent restenosis (ISR) >50% detected by duplex ultrasound was the primary endpoint. Technical success, clinical success, complications within 30 days, and signal intensity abnormalities on diffusion weighted imaging (DWI) after stenting were compared.Results: The 30-day technical success rate was 95.5% (63/66) for SES+EPD vs 100% (70/70) for BES without EPD (p=0.072). DWI at 24 hours poststenting showed 2 hyperintense lesions in 2 (3.3%) SES + EPD cases and 15 hyperintense lesions in 13 (18.6%) BES patients (p<0.01). At a mean 18-month follow-up, the clinical success rate was 93.9% (62/66) for the SES + EPD group vs 85.7% (60/70) for the BES group (p=0.115). The ISR was seen in 16/70 (22.9%) arteries in the BES group and 2/66 (3.1%) arteries in SES + EPD group (p<0.01). Target vessel revascularization was performed in 7 (10.0%) BES arteries vs none in the SES + EPD group (p<0.01).Conclusion: SES with EPD in the treatment of symptomatic VAOS is technically feasible and safe, with low rates of ISR and significantly reduced thromboembolic events on imaging when compared to BES without EPD. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 22:Number 3(2015:Jun.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 22:Number 3(2015:Jun.)
- Issue Display:
- Volume 22, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 22
- Issue:
- 3
- Issue Sort Value:
- 2015-0022-0003-0000
- Page Start:
- 436
- Page End:
- 444
- Publication Date:
- 2015-06
- Subjects:
- self-expanding stents -- balloon-expandable stents -- vertebral artery -- ostial stenosis -- embolic protection device -- in-stent restenosis -- target vessel revascularization
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602815579406 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7161.xml