Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging. Issue 106 (September 2018)
- Record Type:
- Journal Article
- Title:
- Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging. Issue 106 (September 2018)
- Main Title:
- Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging
- Authors:
- Lenga, Lukas
Czwikla, Rouben
Wichmann, Julian L.
Leithner, Doris
Albrecht, Moritz H.
Booz, Christian
Arendt, Christophe T.
Yel, Ibrahim
D'Angelo, Tommaso
Vogl, Thomas J.
Martin, Simon S. - Abstract:
- Highlights: DECT datasets enable post-processing of noise-optimized VMI+. Low-keV VMI+ reconstructions significantly improve image parameters of hypodense liver metastases from colorectal cancer. Highest SNR and CNR values were found at 40-keV VMI+. Qualitative image evaluation revealed best overall rating scores for 60-keV VMI+ reconstructions. Abstract: Purpose: To assess the value of the noise-optimized virtual monoenergetic imaging (VMI+) technique on quantitative and qualitative image parameters in patients with hypoattenuating liver metastases from colorectal cancer (CRC) at abdominal dual-energy CT (DECT). Materials and Methods: Fifty-three consecutive patients (mean age, 70.3 ± 11.4 years; range, 44–86 years) with histologically proven, hypoattenuating liver metastases from CRC were retrospectively included in this IRB-approved study. DECT datasets were reconstructed as standard linearly-blended M_0.6 image series, traditional virtual monoenergetic images (VMI), and noise-optimized VMI+ series. VMI and VMI+ reconstructions were obtained at energy levels ranging from 40 to 100-keV with 10-keV increments. Signal attenuation of liver parenchyma and liver metastases was measured to calculate signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Each image series was subjectively rated by three blinded radiologists with regard to image quality, lesion delineation, and image noise using a five-point Likert scale. Results: Quantitative image quality parameters peaked atHighlights: DECT datasets enable post-processing of noise-optimized VMI+. Low-keV VMI+ reconstructions significantly improve image parameters of hypodense liver metastases from colorectal cancer. Highest SNR and CNR values were found at 40-keV VMI+. Qualitative image evaluation revealed best overall rating scores for 60-keV VMI+ reconstructions. Abstract: Purpose: To assess the value of the noise-optimized virtual monoenergetic imaging (VMI+) technique on quantitative and qualitative image parameters in patients with hypoattenuating liver metastases from colorectal cancer (CRC) at abdominal dual-energy CT (DECT). Materials and Methods: Fifty-three consecutive patients (mean age, 70.3 ± 11.4 years; range, 44–86 years) with histologically proven, hypoattenuating liver metastases from CRC were retrospectively included in this IRB-approved study. DECT datasets were reconstructed as standard linearly-blended M_0.6 image series, traditional virtual monoenergetic images (VMI), and noise-optimized VMI+ series. VMI and VMI+ reconstructions were obtained at energy levels ranging from 40 to 100-keV with 10-keV increments. Signal attenuation of liver parenchyma and liver metastases was measured to calculate signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Each image series was subjectively rated by three blinded radiologists with regard to image quality, lesion delineation, and image noise using a five-point Likert scale. Results: Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 8.1 ± 3.4; CNR, 6.5 ± 2.6) with statistically significant differences in comparison with standard reconstructions and all traditional VMI series ( P ≤ 0.001). Qualitative image analysis revealed best rating scores for 60-keV VMI+ series (median, 5) with significant differences compared to linearly-blended M_0.6 and all traditional VMI series ( P ≤ 0.001). Lesion delineation showed significantly superior ratings for 40-keV VMI+ series compared to all other reconstructions (median, 5) ( P ≤ 0.001). Conclusion: Low-keV VMI+ reconstructions demonstrate significantly increased quantitative and qualitative image quality parameters in patients with hypoattenuating liver metastases from CRC in comparison with standard reconstructions and traditional VMI series at abdominal DECT. Best lesion delineation can be achieved at 40-keV VMI+. … (more)
- Is Part Of:
- European journal of radiology. Issue 106(2018)
- Journal:
- European journal of radiology
- Issue:
- Issue 106(2018)
- Issue Display:
- Volume 106, Issue 106 (2018)
- Year:
- 2018
- Volume:
- 106
- Issue:
- 106
- Issue Sort Value:
- 2018-0106-0106-0000
- Page Start:
- 184
- Page End:
- 191
- Publication Date:
- 2018-09
- Subjects:
- Dual-energy CT -- Virtual monoenergetic imaging -- Colorectal cancer -- Liver metastases -- Quantitative imaging
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2018.07.027 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7166.xml