Luminescence characteristics of some common polyester fabrics: Application to emergency dosimetry. (November 2017)
- Record Type:
- Journal Article
- Title:
- Luminescence characteristics of some common polyester fabrics: Application to emergency dosimetry. (November 2017)
- Main Title:
- Luminescence characteristics of some common polyester fabrics: Application to emergency dosimetry
- Authors:
- Bossin, Lily
Bailiff, Ian K.
Terry, Ian - Abstract:
- Abstract: A set of garment polyester-mix fabrics was tested for their potential suitability as surrogate dosimetry materials using optically and thermally stimulated luminescence techniques. A strong native blue-stimulated optically stimulated luminescence and thermoluminescence signal was observed with unirradiated samples, but this could be avoided by measurement of infra-red stimulated luminescence, and a sample of blue polyester-cotton mix fabric exhibited particularly high sensitivity to radiation dose. However, near complete fading at room temperature within several hours and rapid bleaching of the signal when exposed to daylight limit the deployment of this mode of measurement. The fading behaviour is critically dependent on the atmosphere in which the material is measured and on the storage conditions, where a reduction in oxygen significantly reduces the rate of fading. A cathodoluminescence study of the samples performed in a scanning electron microscope revealed complex emission spectra obtained with spatially integrated measurements and, in one fabric examined in more detail, the spatially resolved emission was found to vary in intensity and wavelength within the polyester fibre filaments which is likely to be associated with differences in crystallinity. Highlights: Polyester garment fabric investigated as a surrogate dosimetry material for emergency applications using luminescence techniques. Cathodoluminescence analysis indicated multiple emission bands andAbstract: A set of garment polyester-mix fabrics was tested for their potential suitability as surrogate dosimetry materials using optically and thermally stimulated luminescence techniques. A strong native blue-stimulated optically stimulated luminescence and thermoluminescence signal was observed with unirradiated samples, but this could be avoided by measurement of infra-red stimulated luminescence, and a sample of blue polyester-cotton mix fabric exhibited particularly high sensitivity to radiation dose. However, near complete fading at room temperature within several hours and rapid bleaching of the signal when exposed to daylight limit the deployment of this mode of measurement. The fading behaviour is critically dependent on the atmosphere in which the material is measured and on the storage conditions, where a reduction in oxygen significantly reduces the rate of fading. A cathodoluminescence study of the samples performed in a scanning electron microscope revealed complex emission spectra obtained with spatially integrated measurements and, in one fabric examined in more detail, the spatially resolved emission was found to vary in intensity and wavelength within the polyester fibre filaments which is likely to be associated with differences in crystallinity. Highlights: Polyester garment fabric investigated as a surrogate dosimetry material for emergency applications using luminescence techniques. Cathodoluminescence analysis indicated multiple emission bands and complex spatial variation. Measurement of infrared stimulated luminescence (IRSL) avoids a strong native signal observed with unirradiated fabric detected using OSL and TL. The IRSL signal fades significantly within several hours, but the removal of oxygen can significantly enhance radiation sensitivity and reduce the fading rate. … (more)
- Is Part Of:
- Radiation measurements. Volume 106(2017:Nov.)
- Journal:
- Radiation measurements
- Issue:
- Volume 106(2017:Nov.)
- Issue Display:
- Volume 106 (2017)
- Year:
- 2017
- Volume:
- 106
- Issue Sort Value:
- 2017-0106-0000-0000
- Page Start:
- 436
- Page End:
- 442
- Publication Date:
- 2017-11
- Subjects:
- Emergency dosimetry -- OSL -- TL -- Polymers -- Polyester fabrics
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2017.05.017 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7159.xml