Performance of the BacT/Alert Virtuo Microbial Detection System for the culture of sterile body fluids: prospective multicentre study. (September 2018)
- Record Type:
- Journal Article
- Title:
- Performance of the BacT/Alert Virtuo Microbial Detection System for the culture of sterile body fluids: prospective multicentre study. (September 2018)
- Main Title:
- Performance of the BacT/Alert Virtuo Microbial Detection System for the culture of sterile body fluids: prospective multicentre study
- Authors:
- She, R.C.
Romney, M.G.
Jang, W.
Walker, T.
Karichu, J.K.
Richter, S.S. - Abstract:
- Abstract: Objectives: Continuous monitoring blood culture systems are commonly used for sterile body fluid cultures. In this multicentre study, we evaluated the performance of the new-generation BacT/Alert Virtuo system compared to the BacT/Alert 3D and conventional culture for the recovery of microorganisms from sterile body fluids. Methods: Peritoneal, cerebrospinal, pericardial, pleural and synovial fluids from adult patients submitted for culture were collected from three different centres. Specimens were inoculated into two bottles of the same bottle type (SA, SN, FA Plus or FN Plus) in equal volumes for simultaneous incubation in the Virtuo and 3D instruments. Each specimen was also Gram stained and seeded to solid media. Results: A total of 811 specimens were inoculated to 1257 bottle pairs. The Virtuo and 3D showed equivalent recovery of clinically significant microorganisms (127/155, 81.9%, vs. 126/155, 81.3%, respectively). Solid media cultures recovered fewer pathogens than either continuous monitoring system (95/155, 61.3%, p <0.001), including significantly fewer Enterobacteriaceae and enterococci. The Virtuo was significantly faster than the 3D in median time to detection of isolates from the same specimen (12.5 (range, 2.8–101.5) hours vs. 15.5 (range, 4.3–78.5) hours, p <0.001). Direct specimen Gram stain detected the eventual pathogen in 30 (26.1%) of 115 significant positive specimens. Conclusions: The BacT/Alert Virtuo system was equivalent to the 3DAbstract: Objectives: Continuous monitoring blood culture systems are commonly used for sterile body fluid cultures. In this multicentre study, we evaluated the performance of the new-generation BacT/Alert Virtuo system compared to the BacT/Alert 3D and conventional culture for the recovery of microorganisms from sterile body fluids. Methods: Peritoneal, cerebrospinal, pericardial, pleural and synovial fluids from adult patients submitted for culture were collected from three different centres. Specimens were inoculated into two bottles of the same bottle type (SA, SN, FA Plus or FN Plus) in equal volumes for simultaneous incubation in the Virtuo and 3D instruments. Each specimen was also Gram stained and seeded to solid media. Results: A total of 811 specimens were inoculated to 1257 bottle pairs. The Virtuo and 3D showed equivalent recovery of clinically significant microorganisms (127/155, 81.9%, vs. 126/155, 81.3%, respectively). Solid media cultures recovered fewer pathogens than either continuous monitoring system (95/155, 61.3%, p <0.001), including significantly fewer Enterobacteriaceae and enterococci. The Virtuo was significantly faster than the 3D in median time to detection of isolates from the same specimen (12.5 (range, 2.8–101.5) hours vs. 15.5 (range, 4.3–78.5) hours, p <0.001). Direct specimen Gram stain detected the eventual pathogen in 30 (26.1%) of 115 significant positive specimens. Conclusions: The BacT/Alert Virtuo system was equivalent to the 3D system in organism recovery from sterile body fluid culture but showed faster detection of growth as a result of design enhancements. … (more)
- Is Part Of:
- Clinical microbiology and infection. Volume 24:Number 9(2018)
- Journal:
- Clinical microbiology and infection
- Issue:
- Volume 24:Number 9(2018)
- Issue Display:
- Volume 24, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 24
- Issue:
- 9
- Issue Sort Value:
- 2018-0024-0009-0000
- Page Start:
- 992
- Page End:
- 996
- Publication Date:
- 2018-09
- Subjects:
- Blood culture bottles -- Continuous monitoring -- Culture media -- Peritoneal -- Pleural
Medical microbiology -- Periodicals
Diagnostic microbiology -- Periodicals
Communicable diseases -- Periodicals
Infection -- Periodicals
616.01 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1469-0691 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.cmi.2017.12.011 ↗
- Languages:
- English
- ISSNs:
- 1198-743X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.305520
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7159.xml