Hemodynamics through the congenitally bicuspid aortic valve: a computational fluid dynamics comparison of opening orifice area and leaflet orientation. (November 2016)
- Record Type:
- Journal Article
- Title:
- Hemodynamics through the congenitally bicuspid aortic valve: a computational fluid dynamics comparison of opening orifice area and leaflet orientation. (November 2016)
- Main Title:
- Hemodynamics through the congenitally bicuspid aortic valve: a computational fluid dynamics comparison of opening orifice area and leaflet orientation
- Authors:
- Mei, Sen
de Souza Júnior, Francisco S.N.
Kuan, May Y.S.
Green, Naomi C.
Espino, Daniel M. - Abstract:
- A computational fluid dynamics model of a bicuspid aortic valve has been developed using idealised three-dimensional geometry. The aim was to compare how the orifice area and leaflet orientation affect the hemodynamics of a pure bicuspid valve. By applying physiologic material properties and boundary conditions, blood flow shear stresses were predicted during peak systole. A reduced orifice area altered blood velocity, the pressure drop across the valve and the wall shear stress through the valve. Bicuspid models predicted impaired blood flow similar to a stenotic valve, but the flow patterns were specific to leaflet orientation. Flow patterns developed in bicuspid aortic valves, such as helical flow, were sensitive to cusp orientation. In conclusion, the reduced opening area of a bicuspid aortic valve amplifies any impaired hemodynamics, but cusp orientation determines subsequent flow patterns which may determine the specific regions downstream from the valve most at risk of clinical complications.
- Is Part Of:
- Perfusion. Volume 31:Number 8(2016)
- Journal:
- Perfusion
- Issue:
- Volume 31:Number 8(2016)
- Issue Display:
- Volume 31, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2016-0031-0008-0000
- Page Start:
- 683
- Page End:
- 690
- Publication Date:
- 2016-11
- Subjects:
- bicuspid aortic valve -- computational fluid dynamics -- congenital malformation -- hemodynamics
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0267659116656775 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7145.xml