Should we change the cannulation site for right subclavian artery cannulation? An experimental study with a newly designed cannula. (November 2016)
- Record Type:
- Journal Article
- Title:
- Should we change the cannulation site for right subclavian artery cannulation? An experimental study with a newly designed cannula. (November 2016)
- Main Title:
- Should we change the cannulation site for right subclavian artery cannulation? An experimental study with a newly designed cannula
- Authors:
- Cakir, Habib
Kestelli, Mert
Yurekli, Ismail
Eygi, Bortecin
Iscan, Sahin
Isık, Yasemin
Aşar, Kamil
Ogut, Hasan - Abstract:
- Background: In this experimental study, we primarily aimed to show the hemodynamic effects and superiority of this newly designed cannula for perfusion compared to standard subclavian cannulation. The new cannula (Figure 1) allows bidirectional axial flow and it directly fits in the brachiocephalic trunk (innominate artery). Methods: We used a cardiopulmonary bypass roller pump, reservoir, 3/8- 1/2- 1/4-inch Y-connectors and tubing set. Lines were set as seen in Figures 2, 3, 4 and 5. The anatomy of the aorta (ascending, arch, branches, descending) was mimicked, using tubing sets with different sizes and the connectors yielding similar angles and configurations. In this experimental vascular system, systemic vascular resistance was created with partial clamping of the common tubing set. The cannulation sites were created in the subclavian artery and the innominate artery. Perfusion was established with the same pump rate and the same occlusion pressures (systemic vascular resistance). The pressure readings were obtained in the right carotid artery, the left carotid artery and the left subclavian artery. Results: These experimental models of vasculature allowed us to measure pressures in the carotid system for different cannulation set-ups, using both our newly designed double-outflow cannula, which was introduced via the innominate artery, and the standard arterial cannula, which was introduced via the subclavian artery. Higher pressure recordings were obtained in theBackground: In this experimental study, we primarily aimed to show the hemodynamic effects and superiority of this newly designed cannula for perfusion compared to standard subclavian cannulation. The new cannula (Figure 1) allows bidirectional axial flow and it directly fits in the brachiocephalic trunk (innominate artery). Methods: We used a cardiopulmonary bypass roller pump, reservoir, 3/8- 1/2- 1/4-inch Y-connectors and tubing set. Lines were set as seen in Figures 2, 3, 4 and 5. The anatomy of the aorta (ascending, arch, branches, descending) was mimicked, using tubing sets with different sizes and the connectors yielding similar angles and configurations. In this experimental vascular system, systemic vascular resistance was created with partial clamping of the common tubing set. The cannulation sites were created in the subclavian artery and the innominate artery. Perfusion was established with the same pump rate and the same occlusion pressures (systemic vascular resistance). The pressure readings were obtained in the right carotid artery, the left carotid artery and the left subclavian artery. Results: These experimental models of vasculature allowed us to measure pressures in the carotid system for different cannulation set-ups, using both our newly designed double-outflow cannula, which was introduced via the innominate artery, and the standard arterial cannula, which was introduced via the subclavian artery. Higher pressure recordings were obtained in the carotid system with the new cannula introduced through innominate artery. Conclusion: Higher cerebral perfusion readings were obtained with our newly designed bidirectional cannula introduced via the innominate artery compared to standard cannulation through the right subclavian artery. … (more)
- Is Part Of:
- Perfusion. Volume 31:Number 8(2016)
- Journal:
- Perfusion
- Issue:
- Volume 31:Number 8(2016)
- Issue Display:
- Volume 31, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2016-0031-0008-0000
- Page Start:
- 668
- Page End:
- 675
- Publication Date:
- 2016-11
- Subjects:
- subclavian artery -- cardiopulmonary bypass -- brachiocephalic trunk
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0267659116649254 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7145.xml