Extending the Faraday cup aerosol electrometer based calibration method up to 5 µm. Issue 8 (3rd August 2018)
- Record Type:
- Journal Article
- Title:
- Extending the Faraday cup aerosol electrometer based calibration method up to 5 µm. Issue 8 (3rd August 2018)
- Main Title:
- Extending the Faraday cup aerosol electrometer based calibration method up to 5 µm
- Authors:
- Järvinen, A.
Keskinen, J.
Yli-Ojanperä, J. - Abstract:
- Abstract: A Faraday cup aerosol electrometer based electrical aerosol instrument calibration setup from nanometers up to micrometers has been designed, constructed, and characterized. The set-up utilizes singly charged seed particles, which are grown to the desired size by condensation of diethylhexyl sebacate. The calibration particle size is further selected with a Differential Mobility Analyzer (DMA). For micrometer sizes, a large DMA was designed, constructed, and characterized. The DMA electrical mobility resolution was found to be 7.95 for 20 L/min sheath and 2 L/min sample flows. The calibration is based on comparing the instrument's response against the concentration measured with a reference Faraday cup aerosol electrometer. The set-up produces relatively high concentrations in the micrometer size range (more than 2500 1/cm 3 at 5.3 µm). A low bias flow mixing and splitting between the reference and the instrument was constructed from a modified, large-sized mixer and a four-port flow splitter. It was characterized at different flow rates and as a function of the particle size. Using two of the four outlet ports at equal 1.5 L/min flow rates, the particle concentration bias of the flow splitting was found to be less than ±1% in the size range of 3.6 nm–5.3 µm. The developed calibration set-up was used to define the detection efficiency of a condensation particle counter from 3.6 nm to 5.3 µm with an expanded measurement uncertainty ( k = 2) of less than 4% over theAbstract: A Faraday cup aerosol electrometer based electrical aerosol instrument calibration setup from nanometers up to micrometers has been designed, constructed, and characterized. The set-up utilizes singly charged seed particles, which are grown to the desired size by condensation of diethylhexyl sebacate. The calibration particle size is further selected with a Differential Mobility Analyzer (DMA). For micrometer sizes, a large DMA was designed, constructed, and characterized. The DMA electrical mobility resolution was found to be 7.95 for 20 L/min sheath and 2 L/min sample flows. The calibration is based on comparing the instrument's response against the concentration measured with a reference Faraday cup aerosol electrometer. The set-up produces relatively high concentrations in the micrometer size range (more than 2500 1/cm 3 at 5.3 µm). A low bias flow mixing and splitting between the reference and the instrument was constructed from a modified, large-sized mixer and a four-port flow splitter. It was characterized at different flow rates and as a function of the particle size. Using two of the four outlet ports at equal 1.5 L/min flow rates, the particle concentration bias of the flow splitting was found to be less than ±1% in the size range of 3.6 nm–5.3 µm. The developed calibration set-up was used to define the detection efficiency of a condensation particle counter from 3.6 nm to 5.3 µm with an expanded measurement uncertainty ( k = 2) of less than 4% over the entire size range and less than 2% for most of the measurement points. Copyright © 2018 American Association for Aerosol Research … (more)
- Is Part Of:
- Aerosol science and technology. Volume 52:Issue 8(2018)
- Journal:
- Aerosol science and technology
- Issue:
- Volume 52:Issue 8(2018)
- Issue Display:
- Volume 52, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 8
- Issue Sort Value:
- 2018-0052-0008-0000
- Page Start:
- 828
- Page End:
- 840
- Publication Date:
- 2018-08-03
- Subjects:
- Pramod Kulkarni
Aerosols -- Periodicals
Aerosol Propellants -- Periodicals
Aerosols -- Periodicals
660.294515 - Journal URLs:
- http://www.tandfonline.com/loi/uast20#.VkNQFJUnyig ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/02786826.2018.1472742 ↗
- Languages:
- English
- ISSNs:
- 0278-6826
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0729.835400
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7116.xml