Step-to-step transition work during level and inclined walking using passive and powered ankle–foot prostheses. (June 2016)
- Record Type:
- Journal Article
- Title:
- Step-to-step transition work during level and inclined walking using passive and powered ankle–foot prostheses. (June 2016)
- Main Title:
- Step-to-step transition work during level and inclined walking using passive and powered ankle–foot prostheses
- Authors:
- Russell Esposito, Elizabeth
Aldridge Whitehead, Jennifer M
Wilken, Jason M - Abstract:
- Background: Individuals with leg amputations who use passive prostheses have greater metabolic demands than non-amputees likely due to limited net positive work compared to a biological ankle. New powered ankle–foot prostheses can perform net positive mechanical work to aid push-off capabilities, which may reduce metabolic demands. Objectives: Compare step-to-step transition work and metabolic demand during level and inclined walking using passive and powered ankle-foot prostheses. Study Design: Repeated measures. Methods: Six individuals with transtibial amputation and six able-bodied controls walked at a standardized speed across level ground and up a 5° incline. Calculated measures included mechanical work during step-to-step transitions from the trailing prosthetic to leading intact limb, steady state metabolic rate, and ankle joint kinetics and kinematics. Results: The powered prosthesis generated 63% greater trailing limb step-to-step transition work than the passive during level walking only (p = 0.004). Metabolic rate was lower with the powered prosthesis during level (p = 0.006) but not inclined walking (p = 0.281). The powered prosthesis increased ankle power compared to the passive, to the extent that power was normalized to controls during inclined walking and greater than controls during level walking. Conclusion: The powered prosthesis improved ankle power, metabolic rate, and step-to-step transition work on level ground, with few negative consequences onBackground: Individuals with leg amputations who use passive prostheses have greater metabolic demands than non-amputees likely due to limited net positive work compared to a biological ankle. New powered ankle–foot prostheses can perform net positive mechanical work to aid push-off capabilities, which may reduce metabolic demands. Objectives: Compare step-to-step transition work and metabolic demand during level and inclined walking using passive and powered ankle-foot prostheses. Study Design: Repeated measures. Methods: Six individuals with transtibial amputation and six able-bodied controls walked at a standardized speed across level ground and up a 5° incline. Calculated measures included mechanical work during step-to-step transitions from the trailing prosthetic to leading intact limb, steady state metabolic rate, and ankle joint kinetics and kinematics. Results: The powered prosthesis generated 63% greater trailing limb step-to-step transition work than the passive during level walking only (p = 0.004). Metabolic rate was lower with the powered prosthesis during level (p = 0.006) but not inclined walking (p = 0.281). The powered prosthesis increased ankle power compared to the passive, to the extent that power was normalized to controls during inclined walking and greater than controls during level walking. Conclusion: The powered prosthesis improved ankle power, metabolic rate, and step-to-step transition work on level ground, with few negative consequences on inclines. These results may be used to guide the development and use of actively powered prosthetic devices in high-functioning individuals. Clinical relevance: Overall, powered devices offer biomechanical and metabolic benefits over passive energy storage and return designs on level ground and perform as well as a passive model on inclines. The lower metabolic demand when using the powered device may delay fatigue for individuals with transtibial amputation when walking over level ground. … (more)
- Is Part Of:
- Prosthetics and orthotics international. Volume 40:Number 3(2016:Jun.)
- Journal:
- Prosthetics and orthotics international
- Issue:
- Volume 40:Number 3(2016:Jun.)
- Issue Display:
- Volume 40, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 40
- Issue:
- 3
- Issue Sort Value:
- 2016-0040-0003-0000
- Page Start:
- 311
- Page End:
- 319
- Publication Date:
- 2016-06
- Subjects:
- Energetics -- transtibial -- hill -- biomechanics
Orthopedic apparatus -- Periodicals
Prosthesis -- Periodicals
Implants, Artificial -- Periodicals
617.905 - Journal URLs:
- http://poi.sagepub.com/content/by/year ↗
https://journals.lww.com/poijournal/pages/default.aspx ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/poi ↗
http://www.tandf.co.uk/journals/titles/03093646.asp ↗ - DOI:
- 10.1177/0309364614564021 ↗
- Languages:
- English
- ISSNs:
- 0309-3646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6935.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7140.xml